ترغب بنشر مسار تعليمي؟ اضغط هنا

SQUID-on-tip with single-electron spin sensitivity for high-field and ultra-low temperature nanomagnetic imaging

477   0   0.0 ( 0 )
 نشر من قبل Yonathan Anahory
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Scanning nanoscale superconducting quantum interference devices (nanoSQUIDs) are of growing interest for highly sensitive quantitative imaging of magnetic, spintronic, and transport properties of low-dimensional systems. Utilizing specifically designed grooved quartz capillaries pulled into a sharp pipette, we have fabricated the smallest SQUID-on-tip (SOT) devices with effective diameters down to 39 nm. Integration of a resistive shunt in close proximity to the pipette apex combined with self-aligned deposition of In and Sn, have resulted in SOT with a flux noise of 42 n$Phi_0$Hz$^{-1/2}$, yielding a record low spin noise of 0.29 $mu_B$Hz$^{-1/2}$. In addition, the new SOTs function at sub-Kelvin temperatures and in high magnetic fields of over 2.5 T. Integrating the SOTs into a scanning probe microscope allowed us to image the stray field of a single Fe$_3$O$_4$ nanocube at 300 mK. Our results show that the easy magnetization axis direction undergoes a transition from the (111) direction at room temperature to an in-plane orientation, which could be attributed to the Verwey phase transition in Fe$_3$O$_4$.



قيم البحث

اقرأ أيضاً

Scanning nanoscale superconducting quantum interference devices (SQUIDs) are gaining interest as highly sensitive microscopic magnetic and thermal characterization tools of quantum and topological states of matter and devices. Here we introduce a nov el technique of collimated differential-pressure magnetron sputtering for versatile self aligned fabrication of SQUID on tip (SOT) nanodevices, which cannot be produced by conventional sputtering methods due to their diffusive, rather than the required directional point-source, deposition. The new technique provides access to a broad range of superconducting materials and alloys beyond the elemental superconductors employed in the existing thermal deposition methods, opening the route to greatly enhanced SOT characteristics and functionalities. Utilizing this method, we have developed MoRe SOT devices with sub-50 nm diameter, magnetic flux sensitivity of 1.2 $muPhi_0/Hz^{1/2}$ up to 3 T at 4.2 K, and thermal sensitivity better than 4 $mu K/Hz^{1/2}$ up to 5 T, about five times higher than any previous report, paving the way to nanoscale imaging of magnetic and spintronic phenomena and of dissipation mechanisms in previously inaccessible quantum states of matter.
One of the critical milestones in the intensive pursuit of quantitative nanoscale magnetic imaging tools is achieving the level of sensitivity required for detecting the field generated by the spin magnetic moment {mu}B of a single electron. Supercon ducting quantum interference devices (SQUIDs), which were traditionally the most sensitive magnetometers, could not hitherto reach this goal because of their relatively large effective size (of the order of 1 {mu}m). Here we report self-aligned fabrication of nano-SQUIDs with diameters as small as 46 nm and with an extremely low flux noise of 50 n{Phi}0/Hz^1/2, representing almost two orders of magnitude improvement in spin sensitivity, down to 0.38 {mu}B/Hz^1/2. In addition, the devices operate over a wide range of magnetic fields with 0.6 {mu}B/Hz^1/2 sensitivity even at 1 T. We demonstrate magnetic imaging of vortices in type II superconductor that are 120 nm apart and scanning measurements of AC magnetic fields down to 50 nT. The unique geometry of these nano-SQUIDs that reside on the apex of a sharp tip allows approaching the sample to within a few nm, which paves the way to a new class of single-spin resolved scanning probe microscopy.
103 - M. Wyss , K. Bagani , D. Jetter 2021
Scanning superconducting quantum interference device (SQUID) microscopy is a magnetic imaging technique combining high-field sensitivity with nanometer-scale spatial resolution. State-of-the-art SQUID-on-tip probes are now playing an important role i n mapping correlation phenomena, such as superconductivity and magnetism, which have recently been observed in two-dimensional van der Waals materials. Here, we demonstrate a scanning probe that combines the magnetic and thermal imaging provided by an on-tip SQUID with the tip-sample distance control and topographic contrast of a non-contact atomic force microscope (AFM). We pattern the nanometer-scale SQUID, including its weak-link Josephson junctions, via focused ion beam milling at the apex of a cantilever coated with Nb, yielding a sensor with an effective diameter of 365 nm, field sensitivity of 9.5 $text{nT}/sqrt{text{Hz}}$ and thermal sensitivity of 620 $text{nK}/sqrt{text{Hz}}$, operating in magnetic fields up to 1.0 T. The resulting SQUID-on-lever is a robust AFM-like scanning probe that expands the reach of sensitive nanometer-scale magnetic and thermal imaging beyond what is currently possible.
We calculate the charge sensitivity of a recently demonstrated device where the Josephson inductance of a single Cooper-pair transistor is measured. We find that the intrinsic limit to detector performance is set by oscillator quantum noise. Sensitiv ity better than $10^{-6}$e$/sqrt{mathrm{Hz}}$ is possible with a high $Q$-value $sim 10^3$, or using a SQUID amplifier. The model is compared to experiment, where charge sensitivity $3 times 10^{-5}$e$/sqrt{mathrm{Hz}}$ and bandwidth 100 MHz are achieved.
We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milliKelvin temperatures. The setup relies on the combination of an interferometric ampli- fication scheme and a quarter-wave impedance transformer, allowing the mea- surement of noise power spectral densities with GHz bandwith up to five orders of magnitude below the amplifier noise floor. We simultaneously measure the high frequency conductance of the sample by derivating a portion of the signal to a microwave homodyne detection. We describe the principle of the setup, as well as its implementation and calibration. Finally, we show that our setup allows to fully characterize a subnanosecond on-demand single electron source. More generally, its sensitivity and bandwith make it suitable for applications manipulating single charges at GHz frequencies.