We employ a novel data-enabled predictive control (DeePC) algorithm in voltage source converter (VSC) based high-voltage DC (HVDC) stations to perform safe and optimal wide-area control for power system oscillation damping. Conventional optimal wide-area control is model-based. However, in practice detailed and accurate parametric power system models are rarely available. In contrast, the DeePC algorithm uses only input/output data measured from the unknown system to predict the future trajectories and calculate the optimal control policy. We showcase that the DeePC algorithm can effectively attenuate inter-area oscillations even in the presence of measurement noise, communication delays, nonlinear loads and uncertain load fluctuations. We investigate the performance under different matrix structures as data-driven predictors. Furthermore, we derive a novel Min-Max DeePC algorithm to be applied independently in multiple VSC-HVDC stations to mitigate inter-area oscillations, which enables decentralized and robust optimal wide-area control. Further, we discuss how to relieve the computational burden of the Min-Max DeePC by reducing the dimension of prediction uncertainty and how to leverage disturbance feedback to reduce the conservativeness of robustification. We illustrate our results with high-fidelity, nonlinear, and noisy simulations of a four-area test system.
Data-driven control that circumvents the process of system identification by providing optimal control inputs directly from system data has attracted renewed attention in recent years. In this paper, we focus on understanding the effects of the regul
We introduce a general framework for robust data-enabled predictive control (DeePC) for linear time-invariant (LTI) systems. The proposed framework enables us to obtain model-free optimal control for LTI systems based on noisy input/output data. More
We apply a novel data-enabled predictive control (DeePC) algorithm in grid-connected power converters to perform safe and optimal control. Rather than a model, the DeePC algorithm solely needs input/output data measured from the unknown system to pre
Appropriate greenhouse temperature should be maintained to ensure crop production while minimizing energy consumption. Even though weather forecasts could provide a certain amount of information to improve control performance, it is not perfect and f
In this paper, a phasor measurement unit (PMU)-based wide-area damping control method is proposed to damp the interarea oscillations that threaten the modern power system stability and security. Utilizing the synchronized PMU data, the proposed almos