ﻻ يوجد ملخص باللغة العربية
The radioactive noble gas radon can be a serious background source in the underground particle physics experiments studying processes that deposit energy comparable to its decay products. Low energy solar neutrino measurements at Super-Kamiokande suffer from these backgrounds and therefore require precise characterization of the radon concentration in the detectors ultra-pure water. For this purpose, we have developed a measurement system consisting of a radon extraction column, a charcoal trap, and a radon detector. In this article we discuss the design, calibration, and performance of the radon extraction column. We also describe the design of the measurement system and evaluate its performance, including its background. Using this system we measured the radon concentration in Super-Kamiokandes water between May 2014 and October 2015. The measured radon concentration in the supply lines of the water circulation system was $1.74pm0.14~mathrm{mBq/m^{3}}$ and in the return line was $9.06pm0.58~mathrm{mBq/m^{3}}$. Water sampled from the center region of the detector itself had a concentration of $<0.23~mathrm{mBq/m^{3}}$ ($95%$ C.L.) and water sampled from the bottom region of the detector had a concentration of $2.63pm0.22~mathrm{mBq/m^{3}}$.
To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33$pm$0.07 mBq/m$^{3}$. In this article,
Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics h
The Jiangmen Underground Neutrino Observatory (JUNO), a 20ktons multi-purpose underground liquid scintillator detector, was proposed with the determination of the neutrino mass hierarchy as a primary physics goal. Due to low background requirement of
The measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activi
We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019