ﻻ يوجد ملخص باللغة العربية
Fabry-Perot fiber etalons (FPE) built from three or more reflectors are attractive for a variety of applications including communications and sensing. For accelerating a research and development work, one often desires to use off-the-shelf components to build an FPE with a required transmission profile for a particular application. Usually, multistage FPEs are designed with equal lengths of cavities followed by determination of the required reflectivities for realizing a desired transmission profile. As seen in previous works, fabricated reflectors are usually slightly different from the designed ones leading to departure from the desired transmission profile of the FPE. Here, we show a novel digital synthesis of multistage etalons with off-the-shelf reflectors and unequal lengths of involved cavities. We find that, in contrast to equal cavity lengths, unequal lengths of cavities provide more number of poles in the $z$-domain to achieve a desired multicavity FPE transmission response. For given reflectivities and by determining correct unequal lengths of cavities with our synthesis technique, we demonstrate a design example of increasing the FSR followed by its experimental validation. This work is generalizable to ring resonators, mirrored, and fiber Bragg grating based cavities; enabling the design and optimization of cavity systems for a wide range of applications including lasers, sensors, and filters.
Photonic analog to digital conversion offers promise to overcome the signal-to-noise ratio (SNR) and sample rate trade-off in conventional analog to digital converters (ADCs), critical for modern digital communications and signal analysis. We propose
Digital-to-analog converters (DAC) are indispensable functional units in signal processing instrumentation and wide-band telecommunication links for both civil and military applications. Since photonic systems are capable of high data throughput and
The Coronavirus Disease (COVID-19) has affected 1.8 million people and resulted in more than 110,000 deaths as of April 12, 2020. Several studies have shown that tomographic patterns seen on chest Computed Tomography (CT), such as ground-glass opacit
Particle accelerators that use electromagnetic fields to increase a charged particles energy have greatly advanced the development of science and industry since invention. However, the enormous cost and size of conventional radio-frequency accelerato
We consider enhancing the sensitivity of future gravitational-wave detectors by using double optical spring. When the power, detuning and bandwidth of the two carriers are chosen appropriately, the effect of the double optical spring can be described