ترغب بنشر مسار تعليمي؟ اضغط هنا

Proof of Principle for Ramsey-type Gravity Resonance Spectroscopy with qBounce

93   0   0.0 ( 0 )
 نشر من قبل Ren\\'e Sedmik
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Ultracold neutrons (UCNs) are formidable probes in precision tests of gravity. With their negligible electric charge, dielectric moment, and polarizability they naturally evade some of the problems plaguing gravity experiments with atomic or macroscopic test bodies. Taking advantage of this fact, the qBounce collaboration has developed a technique - gravity resonance spectroscopy (GRS) - to study bound quantum states of UCN in the gravity field of the Earth. This technique is used as a high-precision tool to search for hypothetical Non-Newtonian gravity on the micrometer scale. In the present article, we describe the recently commissioned Ramsey-type GRS setup, give an unambiguous proof of principle, and discuss possible measurements that will be performed.



قيم البحث

اقرأ أيضاً

This work focuses on the control and understanding of a gravitationally interacting elementary quantum system. It offers a new way of looking at gravitation based on quantum interference: an ultracold neutron, a quantum particle, as an object and as a tool. The ultracold neutron as a tool reflects from a mirror in well-defined quantum states in the gravity potential of the earth allowing to apply the concept of gravity resonance spectroscopy (GRS). GRS relies on frequency measurements, which provide a spectacular sensitivity.
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an autom atic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity and specificity to nitrogenous explosives. Detailed simulation of the detector response to electrons and protons generated by the 9.17 MeV gamma-rays was followed by a proof-of-principle experiment, using a mixed gamma-ray and neutron source. Towards this, a prototype capillary detector was assembled, including the associated filling and readout systems. Simulations and experimental results indeed show that proton tracks are distinguishable from electron tracks at relevant energies, on the basis of a criterion that combines track length and light intensity per unit length.
Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive Plate Chamber s (MRPCs) are gaseous detectors which are easy to fabricate, inexpensive and have excellent position and timing resolution. They can be used as a suitable alternative to highly expensive scintillators. For the sole purpose of TOF-PET, a pair of 18 cm $times$ 18 cm, 5 gap, glass-based MRPC modules have been fabricated. Our main aim was to determine the shift in the position of the source (Na-22) with these fabricated MRPCs. In this document, the details of the experimental results will be presented.
Axions and axion-like particles are excellent low-mass dark matter candidates. The MADMAX experiment aims to directly detect galactic axions with masses between $40,mu{rm eV}$ and $400,mu{rm eV}$ by using the axion-induced emission of electromagnetic waves from boundaries between materials of different dielectric constants under a strong magnetic field. Combining many such surfaces, this emission can be significantly enhanced (boosted) using constructive interference and resonances. We present a first proof of principle realization of such a booster system consisting of a copper mirror and up to five sapphire disks. The electromagnetic response of the system is investigated by reflectivity measurements. The mechanical accuracy, calibration process of unwanted reflections and the repeatability of a basic tuning algorithm to place the disks are investigated. We find that for the presented cases the electromagnetic response in terms of the group delay predicted by one-dimensional calculations is sufficiently realized in our setup. The repeatability of the tuning is at the percent level, and would have small impact on the sensitivity of such a booster.
Many experiments investigated the violation of the Pauli Exclusion Principle (PEP) since its discovery in 1925. The VIP (VIolation of the Pauli Principle) experiment tested the PEP by measuring the probability for an external electron to be captured and undergo a 2p to 1s transition during its cascading process, where the 1s state is already occupied by two electrons. This transition is forbidden by the Pauli Exclusion Principle. The VIP experiment resulted in a preliminary upper limit for the probability of the violation of the PEP of 4.7 x 10^{-29}. Currently a setup for the follow-up experiment VIP 2 is under preparation. The goal of this experiment is to improve the upper limit for the violation of the PEP by two orders of magnitude, by different improvements like enhanced energy resolution of the X-ray detectors and by implementing an active shielding. Here we report currently ongoing performance tests of the new parts of the setup.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا