ﻻ يوجد ملخص باللغة العربية
This article proposes a method for the measurement of Phase Noise (PN, or PM noise) and Amplitude Noise (AN, or AM noise) of Digital-to-Analog Converters (DAC) and Direct Digital Synthesizers (DDS) based on modulation-index amplification. The carrier is first reduced by a controlled amount (30-40 dB) by adding a reference signal of nearly equal amplitude and opposite in phase. Then, residual carrier and noise sidebands are amplified and sent to a conventional PN analyzer. The main virtues of our method are: (i) the noise specs of the PN analyzer are relaxed by a factor equal to the carrier suppression ratio; and, (ii) the capability to measure the AN using a PN analyzer, with no need for the analyzer to feature AN measurement. An obvious variant enables AN and PN measurements using an AN analyzer with no PN measurement capability. Such instrument is extremely simple and easy to implement with a power-detector diode followed by a FFT analyzer. Unlike the classical bridge (interferometric) method, there is no need for external line stretcher and variable attenuators because phase and amplitude control is implemented in the device under test. In one case (AD9144), we could measure the noise over 10 decades of frequency. The flicker noise matches the exact $1/f$ law with a maximum discrepancy of $pm1$ dB over 7.5 decades. Thanks to simplicity, reliability, and low background noise, this method has the potential to become the standard method for the AN and PN measurement of DACs and DDSs.
In this paper the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved
Crystalline optical cavities are the foundation of todays state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity cooled to 4 K
We revisit laser intensity noise in the context of stimulated Raman scattering (SRS), which has recently proved to be a key technique to provide label free images of chemical bonds in biological and medical samples. Contrary to most microscopy techni
The Pound-Drever-Hall laser stabilization technique requires a fast, low-noise photodetector. We present a simple photodetector design that uses a transformer as an intermediary between a photodiode and cascaded low-noise radio-frequency amplifiers.
The digital signal processing has greatly simplified the process of phase noise measurements, especially in oscillators, but its applications are largely confined to the frequencies below 400 MHz. We propose a novel transpose frequency technique, whi