ترغب بنشر مسار تعليمي؟ اضغط هنا

Source-Frequency Phase-Referencing Observation of AGNs with KaVA Using Simultaneous Dual-Frequency Receiving

263   0   0.0 ( 0 )
 نشر من قبل Guang-Yao Zhao Ph.D.
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The KVN(Korean VLBI Network)-style simultaneous multi-frequency receiving mode is demonstrated to be promising for mm-VLBI observations. Recently, other Very long baseline interferometry (VLBI) facilities all over the globe start to implement compatible optics systems. Simultaneous dual/multi-frequency VLBI observations at mm wavelengths with international baselines are thus possible. In this paper, we present the results from the first successful simultaneous 22/43 GHz dual-frequency observation with KaVA(KVN and VERA array), including images and astrometric results. Our analysis shows that the newly implemented simultaneous receiving system has brought a significant extension of the coherence time of the 43 GHz visibility phases along the international baselines. The astrometric results obtained with KaVA are consistent with those obtained with the independent analysis of the KVN data. Our results thus confirm the good performance of the simultaneous receiving systems for the non-KVN stations. Future simultaneous observations with more global stations bring even higher sensitivity and micro-arcsecond level astrometric measurements of the targets.



قيم البحث

اقرأ أيضاً

Oxygen-rich Asymptotic Giant Branch (AGB) stars can be intense emitters of SiO ($v$=1 and 2, J=1$rightarrow$0) and H$_2$O maser lines at 43 and 22 GHz, respectively. VLBI observations of the maser emission provide a unique tool to probe the innermost layers of the circumstellar envelopes in AGB stars. Nevertheless, the difficulties in achieving astrometrically aligned water and $v$=1 and $v$=2 SiO maser maps have traditionally limited the physical constraints that can be placed on the SiO maser pumping mechanism. We present phase referenced simultaneous spectral-line VLBI images for the SiO $v$=1 and $v$=2, J=1$rightarrow$0, and H$_2$O maser emission around the AGB star R,LMi, obtained from the Korean VLBI Network (KVN). The simultaneous multi-channel receivers of the KVN offer great possibilities for astrometry in the frequency domain. With this facility we have produced images with bona-fide absolute astrometric registration between high frequency maser transitions of different species to provide the positions of the water maser emission, and the centre of the SiO maser emission, and hence reducing the uncertainty in the proper motion for R,LMi by an order of magnitude over that from Hipparcos. This is the first successful demonstration of source frequency phase referencing for mm-VLBI spectral-line observations and also where the ratio between the frequencies is not an integer.
Atmospheric propagation effects at millimeter wavelengths can significantly alter the phases of radio signals and reduce the coherence time, putting tight constraints on high frequency Very Long Baseline Interferometry (VLBI) observations. In previou s works, it has been shown that non-dispersive (e.g. tropospheric) effects can be calibrated with the frequency phase transfer (FPT) technique. The coherence time can thus be significantly extended. Ionospheric effects, which can still be significant, remain however uncalibrated after FPT as well as the instrumental effects. In this work, we implement a further phase transfer between two FPT residuals (i.e. so-called FPT-square) to calibrate the ionospheric effects based on their frequency dependence. We show that after FPT-square, the coherence time at 3 mm can be further extended beyond 8~hours, and the residual phase errors can be sufficiently canceled by applying the calibration of another source, which can have a large angular separation from the target (>20 deg) and significant temporal gaps. Calibrations for all-sky distributed sources with a few calibrators are also possible after FPT-square. One of the strengths and uniqueness of this calibration strategy is the suitability for high-frequency all-sky survey observations including very weak sources. We discuss the introduction of a pulse calibration system in the future to calibrate the remaining instrumental effects and allowing the possibility of imaging the source structure at high frequencies with FPT-square, where all phases are fully calibrated without involving any additional sources.
KaVA (KVN and VERA Array) is a new combined VLBI array with KVN (Korean VLBI Network) and VERA (VLBI Exploration of Radio Astrometry). First, we briefly review the imaging capabilities of KaVA array which actually achieves more than three times bette r dynamic range than that achieved by VERA alone. The KaVA images clearly show detailed structures of extended radio jets in AGNs. Next, we represent the key science program to be led by KaVA AGN sub working group. We will conduct the monitoring observations of Sgr A* and M87 because of the largeness of their central super-massive black hole angular sizes. The main science goals of the program are (i) testing magnetically-driven-jet paradigm by mapping velocity fields of the M87 jet, and (ii) obtaining tight constraints on physical properties of radio emitting region in Sgr A*.
In 2017, an Atacama Large Millimeter/submillimeter Array (ALMA) high-frequency long baseline campaign was organized to test image capabilities with baselines up to 16 km at submillimeter (submm) wavelengths. We investigated image qualities using ALMA receiver Bands 7, 8, 9, and 10 (285-875 GHz) by adopting band-to-band (B2B) phase referencing in which a phase calibrator is tracked at a lower frequency. For B2B phase referencing, it is expected that a closer phase calibrator to a target can be used, comparing to standard in-band phase referencing. In the first step, it is ensured that an instrumental phase offset difference between low- and high-frequency Bands can be removed using a differential gain calibration in which a phase calibrator is certainly detected while frequency switching. In the next step, comparative experiments are arranged to investigate the image quality between B2B and in-band phase referencing with phase calibrators at various separation angles. In the final step, we conducted long baseline imaging tests for a quasar at 289 GHz in Band 7 and 405 GHz in Band 8 and complex structure sources of HL Tau and VY CMa at ~670 GHz in Band 9. The B2B phase referencing was successfully applied, allowing us to achieve an angular resolution of 14x11 and 10x8 mas for HL Tau and VY CMa, respectively. There is a high probability of finding a low-frequency calibrator within 5.4 deg in B2B phase referencing, bright enough to use an 8 s scan length combined with a 7.5 GHz bandwidth.
We present the performance of the upGREAT heterodyne array receivers on the SOFIA telescope after several years of operations. This instrument is a multi-pixel high resolution (R > 10^7) spectrometer for the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA). The receivers use 7-pixel subarrays configured in a hexagonal layout around a central pixel. The low frequency array receiver (LFA) has 2x7 pixels (dual polarization), and presently covers the 1.83-2.06 THz frequency range, which allows to observe the [CII] and [OI] lines at 158 um and 145 um wavelengths. The high frequency array (HFA) covers the [OI] line at 63 um and is equipped with one polarization at the moment (7 pixels, which can be upgraded in the near future with a second polarization array). The 4.7 THz array has successfully flown using two separate quantum-cascade laser local oscillators from two different groups. NASA completed the development, integration and testing of a dual-channel closed-cycle cryocooler system, with two independently operable He compressors, aboard SOFIA in early 2017 and since then, both arrays can be operated in parallel using a frequency separating dichroic mirror. This configuration is now the prime GREAT configuration and has been added to SOFIAs instrument suite since observing cycle 6.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا