We report on microwave optomechanics measurements performed on a nuclear adiabatic demagnetization cryostat, whose temperature is determined by accurate thermometry from below 500$~mu$K to about 1$~$Kelvin. We describe a method for accessing the on-chip temperature, building on the blue-detuned parametric instability and a standard microwave setup. The capabilities and sensitivity of both the experimental arrangement and the developed technique are demonstrated with a very weakly coupled silicon-nitride doubly-clamped beam mode of about 4$~$MHz and a niobium on-chip cavity resonating around 6$~$GHz. We report on an unstable intrinsic driving force in the coupled microwave-mechanical system acting on the mechanics that appears below typically 100$~$mK. The origin of this phenomenon remains unknown, and deserves theoretical input. It prevents us from performing reliable experiments below typically 10-30$~$mK; however no evidence of thermal decoupling is observed, and we propose that the same features should be present in all devices sharing the microwave technology, at different levels of strengths. We further demonstrate empirically how most of the unstable feature can be annihilated, and speculate how the mechanism could be linked to atomic-scale two level systems. The described microwave/microkelvin facility is part of the EMP platform, and shall be used for further experiments within and below the millikelvin range.



قيم البحث

اقرأ أيضاً

We demonstrate successful dry refrigeration of quantum fluids down to $T=0.16$,mK by using copper nuclear demagnetization stage that is pre-cooled by a pulse-tube-based dilution refrigerator. This type of refrigeration delivers a flexible and simple sub-mK solution to a variety of needs including experiments with superfluid $^3$He. Our central design principle was to eliminate relative vibrations between the high-field magnet and the nuclear refrigeration stage, which resulted in the minimum heat leak of $Q=4.4$,nW obtained in field of 35,mT. For thermometry, we employed a quartz tuning fork immersed into liquid $^3$He. We show that the fork oscillator can be considered as self-calibrating in superfluid $^3$He at the crossover point from hydrodynamic into ballistic quasiparticle regime.
We present measurements of silica optomechanical resonators, known as bottle resonators, passively cooled in a cryogenic environment. These devices possess a suite of properties that make them advantageous for preparation and measurement in the mecha nical ground state, including high mechanical frequency, high optical and mechanical quality factors, and optomechanical sideband resolution. Performing thermometry of the mechanical motion, we find that the optical and mechanical modes demonstrate quantitatively similar laser-induced heating, limiting the lowest average phonon occupation observed to just ~1500. Thermalization to the 9 mK thermal bath would facilitate quantum measurements on these promising nanogram-scale mechanical resonators.
390 - D. Cattiaux , X. Zhou , S. Kumar 2020
We explore the nonlinear dynamics of a cavity optomechanical system. Our realization consisting of a drumhead nano-electro-mechanical resonator (NEMS) coupled to a microwave cavity, allows for a nearly ideal platform to study the nonlinearities arisi ng purely due to radiation-pressure physics. Experiments are performed under a strong microwave Stokes pumping which triggers mechanical self-sustained oscillations. We analyze the results in the framework of an extended nonlinear optomechanical theory, and demonstrate that quadratic and cubic coupling terms in the opto-mechanical Hamiltonian have to be considered. Quantitative agreement with the measurements is obtained considering only genuine geometrical nonlinearities: no thermo-optical instabilities are observed, in contrast with laser-driven systems. Based on these results, we describe a method to quantify nonlinear properties of microwave optomechanical devices. Such a technique, available now in the quantum electro-mechanics toolbox, but completely generic, is mandatory for the development of new schemes where higher-order coupling terms are proposed as a new resource, like Quantum Non-Demolition measurements, or in the search for new fundamental quantum signatures, like Quantum Gravity. We also find that the motion imprints a wide comb of extremely narrow peaks in the microwave output field, which could also be exploited in specific microwave-based measurements, potentially limited only by the quantum noise of the optical and the mechanical fields for a ground-state cooled NEMS device.
We demonstrate a hybrid architecture consisting of a quantum dot circuit coupled to a single mode of the electromagnetic field. We use single wall carbon nanotube based circuits inserted in superconducting microwave cavities. By probing the nanotube- dot using a dispersive read-out in the Coulomb blockade and the Kondo regime, we determine an electron-photon coupling strength which should enable circuit QED experiments with more complex quantum dot circuits.
142 - T. Frey , P. J. Leek , M. Beck 2012
We present microwave frequency measurements of the dynamic admittance of a quantum dot tunnel coupled to a two-dimensional electron gas. The measurements are made via a high-quality 6.75 GHz on-chip resonator capacitively coupled to the dot. The reso nator frequency is found to shift both down and up close to conductance resonance of the dot corresponding to a change of sign of the reactance of the system from capacitive to inductive. The observations are consistent with a scattering matrix model. The sign of the reactance depends on the detuning of the dot from conductance resonance and on the magnitude of the tunnel rate to the lead with respect to the resonator frequency. Inductive response is observed on a conductance resonance, when tunnel coupling and temperature are sufficiently small compared to the resonator frequency.