ﻻ يوجد ملخص باللغة العربية
The Facility for Rare Isotope Beams (FRIB) at Michigan State University provides a unique opportunity to access some of the nations most specialized scientific resources: radioisotopes. An excess of useful radioisotopes will be formed as FRIB fulfills its basic science mission of providing rare isotope beams. In order for the FRIB beams to reach high-purity, many of the isotopes are discarded and go unused. If harvested, the unused isotopes could enable cutting-edge research for diverse applications ranging from medical therapy and diagnosis to nuclear security. Given that FRIB will have the capability to create about 80 percent of all possible atomic nuclei, harvesting at FRIB will provide a fast path for access to a vast array of isotopes of interest in basic and applied science investigations. To fully realize this opportunity, infrastructure investment is required to enable harvesting and purification of otherwise unused isotopes. An investment in isotope harvesting at FRIB will provide the nation with a powerful resource for development of crucial isotope applications.
To improve the ability of particle identification of the RIBLL2 separator at the HIRFL-CSR complex, a new high-performance detector for measuring fragment starting time and position at the F1 dispersive plane has been constructed and installed, and a
The TexAT (Texas Active Target) detector is a new active-target time projection chamber (TPC) that was built at the Cyclotron Institute Texas A$&$M University. The detector is designed to be of general use for nuclear structure and nuclear astrophysi
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is a
We have developed a method for achieving excellent resolving power in in-flight particle identification of radioactive isotope (RI) beams at the BigRIPS fragment separator at the RIKEN Nishina Center RI Beam Factory (RIBF). In the BigRIPS separator,
Waveform feature is one of the requirements for the FRIB LLRF controllers. It is desired that the LLRF con-trollers store the internal data (e.g. the amplitude and phase information of forward/reverse/cavity signals) for at least one second of sample