ترغب بنشر مسار تعليمي؟ اضغط هنا

Optimal conditions for Bell test using spontaneous parametric down-conversion sources

65   0   0.0 ( 0 )
 نشر من قبل Yoshiaki Tsujimoto
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We theoretically and experimentally investigate the optimal conditions for the Bell experiment using spontaneous parametric down conversion (SPDC) sources. In theory, we show that relatively large average photon number (typically $sim$0.5) is desirable to observe the maximum violation of the Clauser-Horne-Shimony-Holt (CHSH) inequality. In experiment, we perform the Bell experiment without postselection using polarization entangled photon pairs at 1550 nm telecommunication wavelength generated from SPDC sources. While the violation of the CHSH inequality is not directly observed due to the overall detection efficiencies of our system, the experimental values agree well with those obtained by the theory with experimental imperfections. Furthermore, in the range of the small average photon numbers ($leq0.1$), we propose and demonstrate a method to estimate the ideal CHSH value intrinsically contained in the tested state from the lossy experimental data without assuming the input quantum state.



قيم البحث

اقرأ أيضاً

An important step for photonic quantum technologies is the demonstration of a quantum advantage through boson sampling. In order to prevent classical simulability of boson sampling, the photons need to be almost perfectly identical and almost without losses. These two requirements are connected through spectral filtering, improving one leads to a decrease of the other. A proven method of generating single photons is spontaneous parametric downconversion (SPDC). We show that an optimal trade-off between indistinguishability and losses can always be found for SPDC. We conclude that a 50-photon scattershot boson-sampling experiment using SPDC sources is possible from a computational complexity point of view. To this end, we numerically optimize SPDC sources under the regime of weak pumping and with a single spatial mode.
Spontaneous Parametric Down-Conversion (SPDC), also known as parametric fluorescence, parametric noise, parametric scattering and all various combinations of the abbreviation SPDC, is a non-linear optical process where a photon spontaneously splits i nto two other photons of lower energies. One would think that this article is about particle physics and yet it is not, as this process can occur fairly easily on a day to day basis in an optics laboratory. Nowadays, SPDC is at the heart of many quantum optics experiments for applications in quantum cryptography, quantum simulation, quantum metrology but also for testing fundamentals laws of physics in quantum mechanics. In this article, we will focus on the physics of this process and highlight few important properties of SPDC. There will be two parts: a first theoretical one showing the particular quantum nature of SPDC and the second part, more experimental and in particular focusing on applications of parametric down-conversion. This is clearly a non-exhaustive article about parametric down-conversion as there is a tremendous literature on the subject, but it gives the necessary first elements needed for a novice student or researcher to work on SPDC sources of light.
Miniaturised entangled photon sources are highly demanded for the development of integrated quantum photonics. Since the invention of subwavelength optical metasurfaces and their successes at replacing bulky optical components, the possibility of imp lementing entangled photon sources on such devices is actively investigated. Here, as a first step towards the development of quantum optical metasurfaces (QOM), we demonstrate photon pair generation via spontaneous parametric down-conversion (SPDC) from subwavelength films. We achieved photon pair generation with a high coincidence-to-accidental ratio in lithium niobate and gallium phosphide nanofilms. In addition, we have measured the SPDC frequency spectrum via fibre spectroscopy, obtaining photon pairs with a spectral bandwidth of 500;nm, limited only by the overall detection efficiency. Moreover, we have observed the vacuum field enhancement due to a Fabry-Perot resonance inside the nonlinear films. Our experiments lay the groundwork for the future development of flat SPDC sources, including QOM.
We present an experimental characterization of the statistics of multiple photon pairs produced by spontaneous parametric down-conversion realized in a nonlinear medium pumped by high-energy ultrashort pulses from a regenerative amplifier. The photon number resolved measurement has been implemented with the help of a fiber loop detector. We introduce an effective theoretical description of the observed statistics based on parameters that can be assigned direct physical nterpretation. These parameters, determined for our source from the collected experimental data, characterize the usefulness of down-conversion sources in multiphoton interference schemes that underlie protocols for quantum information processing and communication.
We present a violation of the CHSH inequality without the fair sampling assumption with a continuously pumped photon pair source combined with two high efficiency superconducting detectors. Due to the continuous nature of the source, the choice of th e duration of each measurement round effectively controls the average number of photon pairs participating in the Bell test. We observe a maximum violation of S= 2.01602(32) with average number of pairs per round of ~0.32, compatible with our system overall detection efficiencies. Systems that violate a Bell inequality are guaranteed to generate private randomness, with the randomness extraction rate depending on the observed violation and on the repetition rate of the Bell test. For our realization, the optimal rate of randomness generation is a compromise between the observed violation and the duration of each measurement round, with the latter realistically limited by the detection time jitter. Using an extractor composably secure against quantum adversary with quantum side information, we calculate an asymptotic rate of ~1300 random bits/s. With an experimental run of 43 minutes, we generated 617,920 random bits, corresponding to ~240 random bits/s.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا