ترغب بنشر مسار تعليمي؟ اضغط هنا

MagAO-X: project status and first laboratory results

302   0   0.0 ( 0 )
 نشر من قبل Jared Males
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

MagAO-X is an entirely new extreme adaptive optics system for the Magellan Clay 6.5 m telescope, funded by the NSF MRI program starting in Sep 2016. The key science goal of MagAO-X is high-contrast imaging of accreting protoplanets at H$alpha$. With 2040 actuators operating at up to 3630 Hz, MagAO-X will deliver high Strehls (>70%), high resolution (19 mas), and high contrast ($< 1times10^{-4}$) at H$alpha$ (656 nm). We present an overview of the MagAO-X system, review the system design, and discuss the current project status.



قيم البحث

اقرأ أيضاً

The MagAO-X instrument is an upgrade of the Magellan AO system that will introduce extreme adaptive optics capabilities for high-contrast imaging at visible and near-infrared wavelengths. A central component of this system is a 2040-actuator microele ctromechanical (MEMS) deformable mirror (DM) from Boston Micromachines Corp. (BMC) that will operate at 3.63 kHz for high-order wavefront control. Two additional DMs from ALPAO will perform low-order and non-common-path science-arm wavefront correction. The accuracy of the wavefront correction is limited by our ability to command these DMs to a desired shape, which requires a careful characterization of each DM surface. We have developed a characterization pipeline that uses a Zygo Verifire Interferometer to measure the surface response and a Karhunen-Lo`eve transform to remove noise from our measurements. We present our progress in the characterization process and the results of our pipeline applied to an ALPAO DM97 and a BMC Kilo-DM, demonstrating the ability to drive the DMs to a flat of $lesssim$ 2nm and $lesssim$ 4nm RMS in our beam footprint on the University of Arizona Wavefront Control (UAWFC) testbed.
MagAO is the new adaptive optics system with visible-light and infrared science cameras, located on the 6.5-m Magellan Clay telescope at Las Campanas Observatory, Chile. The instrument locks on natural guide stars (NGS) from 0$^mathrm{th}$ to 16$^mat hrm{th}$ $R$-band magnitude, measures turbulence with a modulating pyramid wavefront sensor binnable from 28x28 to 7x7 subapertures, and uses a 585-actuator adaptive secondary mirror (ASM) to provide flat wavefronts to the two science cameras. MagAO is a mutated clone of the similar AO systems at the Large Binocular Telescope (LBT) at Mt. Graham, Arizona. The high-level AO loop controls up to 378 modes and operates at frame rates up to 1000 Hz. The instrument has two science cameras: VisAO operating from 0.5-1 $mu$m and Clio2 operating from 1-5 $mu$m. MagAO was installed in 2012 and successfully completed two commissioning runs in 2012-2013. In April 2014 we had our first science run that was open to the general Magellan community. Observers from Arizona, Carnegie, Australia, Harvard, MIT, Michigan, and Chile took observations in collaboration with the MagAO instrument team. Here we describe the MagAO instrument, describe our on-sky performance, and report our status as of summer 2014.
We review astronomical results in the visible (lambda <1 micron) with adaptive optics and note the status the MagAO system and the recent upgrade to visible cameras Simultaneous/Spectra Differential Imager (SDI to SDI+) mode. Since mid-2013 there has been a rapid increase visible AO with over 50 refereed science papers published in just 2015-2016 timeframe. The main focus of this paper is another large (D=6.5m Magellan telescope) AO system (MagAO) which has been very productive in the visible (particularly at the H-alpha emission line). MagAO is an advanced Adaptive Secondary Mirror (ASM) AO system at the Magellan in Chile. This ASM secondary has 585 actuators with <1 msec response times (0.7 ms typically). MagAO utilizes a 1 kHz pyramid wavefront sensor (PWFS). The relatively small actuator pitch (~22 cm/subap, 300 modes, upgraded to 30 pix dia. PWFS) allows moderate Strehls to be obtained in the visible (0.63-1.05 microns). Long exposures (60s) achieve <30mas resolutions and 30% Strehls at 0.62 microns (r) with the VisAO camera (0.5-1.0 microns) in 0.5 seeing with bright R < 9 mag stars (~10% Strehls can be obtained on fainter R~12 mag guide stars). Differential Spectral Imaging (SDI) at H-alpha has been very important for accreting exoplanet detection. There is also a 1-5micron science camera (Clio; Morzinski et al. 2016). These capabilities have led to over 35 MagAO refereed science publications. Here we review the key steps to having good performance in the visible and review the exciting new AO visible science opportunities and science results. The recent rapid increase in the scientific publications and power of visible AO is due to the maturity of the next-generation of AO systems and our new ability probe circumstellar regions with very high (10-30 mas) spatial resolutions that would otherwise require much larger (>10m) diameter telescopes in the infrared.
Here we review the current optical mechanical design of MagAO-X. The project is post-PDR and has finished the design phase. The design presented here is the baseline to which all the optics and mechanics have been fabricated. The optical/mechanical p erformance of this novel extreme AO design will be presented here for the first time. Some highlights of the design are: 1) a floating, but height stabilized, optical table; 2) a Woofer tweeter (2040 actuator BMC MEMS DM) design where the Woofer can be the current f/16 MagAO ASM or, more likely, fed by the facility f/11 static secondary to an ALPAO DM97 woofer; 3) 22 very compact optical mounts that have a novel locking clamp for additional thermal and vibrational stability; 4) A series of four pairs of super-polished off-axis parabolic (OAP) mirrors with a relatively wide FOV by matched OAP clocking; 5) an advanced very broadband (0.5-1.7micron) ADC design; 6) A Pyramid (PWFS), and post-coronagraphic LOWFS NCP wavefront sensor; 7) a vAPP coronagraph for starlight suppression. Currently all the OAPs have just been delivered, and all the rest of the optics are in the lab. Most of the major mechanical parts are in the lab or instrument, and alignment of the optics has occurred for some of the optics (like the PWFS) and most of the mounts. First light should be in 2019A.
We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental calibration of optical telescopes. The heart of DICE is an i llumination device composed of 24 narrow-spectrum, high-intensity, light-emitting diodes (LED) chosen to cover the ultraviolet-to-near-infrared spectral range. It implements a point-like source placed at a finite distance from the telescope entrance pupil, yielding a flat field illumination that covers the entire field of view of the imager. The purpose of this system is to perform a lightweight routine monitoring of the imager passbands with a precision better than 5 per-mil on the relative passband normalisations and about 3{AA} on the filter cutoff positions. The light source is calibrated on a spectrophotometric bench. As our fundamental metrology standard, we use a photodiode calibrated at NIST. The radiant intensity of each beam is mapped, and spectra are measured for each LED. All measurements are conducted at temperatures ranging from 0{deg}C to 25{deg}C in order to study the temperature dependence of the system. The photometric and spectroscopic measurements are combined into a model that predicts the spectral intensity of the source as a function of temperature. We find that the calibration beams are stable at the $10^{-4}$ level -- after taking the slight temperature dependence of the LED emission properties into account. We show that the spectral intensity of the source can be characterised with a precision of 3{AA} in wavelength. In flux, we reach an accuracy of about 0.2-0.5% depending on how we understand the off-diagonal terms of the error budget affecting the calibration of the NIST photodiode. With a routine 60-mn calibration program, the apparatus is able to constrain the passbands at the targeted precision levels.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا