ترغب بنشر مسار تعليمي؟ اضغط هنا

kima: Exoplanet detection in radial velocities

114   0   0.0 ( 0 )
 نشر من قبل Jo\\~ao Faria
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The radial-velocity (RV) method is one of the most successful in the detection of exoplanets, but is hindered by the intrinsic RV variations of the star, which can easily mimic or hide true planetary signals. kima is a package for the detection and characterization of exoplanets using RV data. It fits a sum of Keplerian curves to a timeseries of RV measurements and calculates the evidence for models with a fixed number Np of Keplerian signals, or after marginalising over Np. Moreover, kima can use a GP with a quasi-periodic kernel as a noise model, to deal with activity-induced signals. The hyperparameters of the GP are inferred together with the orbital parameters. The code is written in C++, but includes a helper Python package, pykima, which facilitates the analysis of the results.



قيم البحث

اقرأ أيضاً

High fidelity iodine spectra provide the wavelength and instrument calibration needed to extract precise radial velocities (RVs) from stellar spectral observations taken through iodine cells. Such iodine spectra are usually taken by a Fourier Transfo rm Spectrometer (FTS). In this work, we investigated the reason behind the discrepancy between two FTS spectra of the iodine cell used for precise RV work with the High Resolution Spectrograph (HRS) at the Hobby-Eberly Telescope. We concluded that the discrepancy between the two HRS FTS spectra was due to temperature changes of the iodine cell. Our work demonstrated that the ultra-high resolution spectra taken by the TS12 arm of the Tull Spectrograph One at McDonald Observatory are of similar quality to the FTS spectra and thus can be used to validate the FTS spectra. Using the software IodineSpec5, which computes the iodine absorption lines at different temperatures, we concluded that the HET/HRS cell was most likely not at its nominal operating temperature of 70 degree Celsius during its FTS scan at NIST or at the TS12 measurement. We found that extremely high resolution echelle spectra (R>200,000) can validate and diagnose deficiencies in FTS spectra. We also recommend best practices for temperature control and nightly calibration of iodine cells.
The EXtreme PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, $R=137,500$, optical spectrograph. It was recently commissioned at the 4.3-m Lowell Discovery Telescope (LDT) near Flagstaff, Arizona. The spectrograph was desig ned with a target radial-velocity (RV) precision of 30$mathrm{~cm~s^{-1}}$. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first for an on-sky, optical, fiber-fed spectrograph to employ many novel techniques---including an extended flat fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and radial-velocity analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3$mathrm{~m~s^{-1}}$ for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual RMS of 0.895$mathrm{~m~s^{-1}}$.
The Second Workshop on Extreme Precision Radial Velocities defined circa 2015 the state of the art Doppler precision and identified the critical path challenges for reaching 10 cm/s measurement precision. The presentations and discussion of key issue s for instrumentation and data analysis and the workshop recommendations for achieving this precision are summarized here. Beginning with the HARPS spectrograph, technological advances for precision radial velocity measurements have focused on building extremely stable instruments. To reach still higher precision, future spectrometers will need to produce even higher fidelity spectra. This should be possible with improved environmental control, greater stability in the illumination of the spectrometer optics, better detectors, more precise wavelength calibration, and broader bandwidth spectra. Key data analysis challenges for the precision radial velocity community include distinguishing center of mass Keplerian motion from photospheric velocities, and the proper treatment of telluric contamination. Success here is coupled to the instrument design, but also requires the implementation of robust statistical and modeling techniques. Center of mass velocities produce Doppler shifts that affect every line identically, while photospheric velocities produce line profile asymmetries with wavelength and temporal dependencies that are different from Keplerian signals. Exoplanets are an important subfield of astronomy and there has been an impressive rate of discovery over the past two decades. Higher precision radial velocity measurements are required to serve as a discovery technique for potentially habitable worlds and to characterize detections from transit missions. The future of exoplanet science has very different trajectories depending on the precision that can ultimately be achieved with Doppler measurements.
The MINiature Exoplanet Radial Velocity Array (MINERVA) is a dedicated observatory of four 0.7m robotic telescopes fiber-fed to a KiwiSpec spectrograph. The MINERVA mission is to discover super-Earths in the habitable zones of nearby stars. This can be accomplished with MINERVAs unique combination of high precision and high cadence over long time periods. In this work, we detail changes to the MINERVA facility that have occurred since our previous paper. We then describe MINERVAs robotic control software, the process by which we perform 1D spectral extraction, and our forward modeling Doppler pipeline. In the process of improving our forward modeling procedure, we found that our spectrographs intrinsic instrumental profile is stable for at least nine months. Because of that, we characterized our instrumental profile with a time-independent, cubic spline function based on the profile in the cross dispersion direction, with which we achieved a radial velocity precision similar to using a conventional sum-of-Gaussians instrumental profile: 1.8 m s$^{-1}$ over 1.5 months on the RV standard star HD 122064. Therefore, we conclude that the instrumental profile need not be perfectly accurate as long as it is stable. In addition, we observed 51 Peg and our results are consistent with the literature, confirming our spectrograph and Doppler pipeline are producing accurate and precise radial velocities.
146 - P. Figueira 2011
The precision of radial velocity (RV) measurements depends on the precision attained on the wavelength calibration. One of the available options is using atmospheric lines as a natural, freely available wavelength reference. Figueira et al. (2010) me asured the RV of O2 lines using HARPS and showed that the scatter was only of ~10 m/s over a timescale of 6 yr. Using a simple but physically motivated empirical model, they demonstrated a precision of 2 m/s, roughly twice the average photon noise contribution. In this paper we take advantage of a unique opportunity to confirm the sensitivity of the telluric absorption lines RV to different atmospheric and observing conditions: by means of contemporaneous in-situ wind measurements by radiosondes. The RV model fitting yielded similar results to that of Figueira et al. (2010), with lower wind magnitude values and varied wind direction. The probes confirmed the average low wind magnitude and suggested that the average wind direction is a function of time as well. The two approaches deliver the same results in what concerns wind magnitude and agree on wind direction when fitting is done in segments of a couple of hours. Statistical tests show that the model provides a good description of the data on all timescales, being always preferable to not fitting any atmospheric variation. The smaller the timescale on which the fitting can be performed (down to a couple of hours), the better the description of the real physical parameters. We conclude then that the two methods deliver compatible results, down to better than 5 m/s and less than twice the estimated photon noise contribution on O2 lines RV measurement. However, we cannot rule out that parameters alpha and gamma (dependence on airmass and zero-point, respectively) have a dependence on time or exhibit some cross-talk with other parameters (abridged).
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا