ترغب بنشر مسار تعليمي؟ اضغط هنا

Improved RF Measurements of SRF Cavity Quality Factors

79   0   0.0 ( 0 )
 نشر من قبل Jeremiah Holzbauer
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English
 تأليف J.P. Holzbauer




اسأل ChatGPT حول البحث

SRF cavity quality factors can be accurately measured using RF-power based techniques only when the cavity is very close to critically coupled. This limitation is from systematic errors driven by non-ideal RF components. When the cavity is not close to critically coupled, these systematic effects limit the accuracy of the measurements. The combination of the complex base-band envelopes of the cavity RF signals in combination with a trombone in the circuit allow the relative calibration of the RF signals to be extracted from the data and systematic effects to be characterized and suppressed. The improved calibration allows accurate measurements to be made over a much wider range of couplings. Demonstration of these techniques during testing of a single-spoke resonator with a coupling factor of near 7 will be presented, along with recommendations for application of these techniques.



قيم البحث

اقرأ أيضاً

Q0 determinations based on RF power measurements are subject to at least three potentially large systematic effects that have not been previously appreciated. Instrumental factors that can systematically bias RF based measurements of Q0 are quantifie d and steps that can be taken to improve the determination of Q0 are discussed.
262 - G. Wu , M. Ge 2012
Magnetic field enhancement has been studied in the past through replica and cavity cutting. Considerable progress of niobium cavity manufacturing and processing has been made since then. Wide variety of single cell cavities has been analyzed through replica technique. Their RF performances were compared in corresponding to geometric RF surface quality. It is concluded that the surface roughness affects cavity performance mostly in secondary role. The other factors must have played primary role in cavity performance limitations.
110 - E. Harms , K. Carlson , B. Chase 2012
Powered operation of Cryomodule 1 (CM-1) at the Fermilab SRF Beam Test Facility began in late 2010. Since then a series of tests first on the eight individual cavities and then the full cryomodule have been performed. We report on the results of thes e tests and lessons learned which will have an impact on future module testing at Fermilab.
103 - R. Madrak , J. Dey , K. Duel 2018
A second harmonic RF cavity which uses perpendicularly biased garnet for frequency tuning is currently being constructed for use in the Fermilab Booster. The cavity will operate at twice the fundamental RF frequency, from ~76 - 106 MHz, and will be t urned on only during injection, and transition or extraction. Its main purpose is to reduce beam loss as required by Fermilabs Proton Improvement Plan (PIP). After three years of optimization and study, the cavity design has been finalized and all constituent parts have been received. We discuss the design aspects of the cavity and its associated systems, component testing, and status of the cavity construction.
162 - Katsuya Yonehara 2012
In order to develop an RF cavity that is applicable for a muon beam cooling channel, a new facility, called Mucool Test Area (MTA) has been built at Fermilab. MTA is a unique facility whose purpose is to test RF cavities in various conditions. There are 201 and 805 MHz high power sources, a 4-Tesla solenoid magnet, a cryogenic system including a Helium liquifier, an explosion proof apparatus to operate gaseous/liquid Hydrogen, and a beam transport line to send an intense H- beam from the Fermilab Linac accelerator to the MTA hall. Recent activities at MTA will be discussed in this document.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا