ترغب بنشر مسار تعليمي؟ اضغط هنا

SENSEI: First Direct-Detection Constraints on sub-GeV Dark Matter from a Surface Run

81   0   0.0 ( 0 )
 نشر من قبل Rouven Essig
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Sub-Electron-Noise Skipper CCD Experimental Instrument (SENSEI) uses the recently developed Skipper-CCD technology to search for electron recoils from the interaction of sub-GeV dark matter particles with electrons in silicon. We report first results from a prototype SENSEI detector, which collected 0.019 gram-days of commissioning data above ground at Fermi National Accelerator Laboratory. These commissioning data are sufficient to set new direct-detection constraints for dark matter particles with masses between ~500 keV and 4 MeV. Moreover, since these data were taken on the surface, they disfavor previously allowed strongly interacting dark matter particles with masses between ~500 keV and a few hundred MeV. We discuss the implications of these data for several dark matter candidates, including one model proposed to explain the anomalously large 21-cm signal observed by the EDGES Collaboration. SENSEI is the first experiment dedicated to the search for electron recoils from dark matter, and these results demonstrate the power of the Skipper-CCD technology for dark matter searches.



قيم البحث

اقرأ أيضاً

We present new direct-detection constraints on eV-to-GeV dark matter interacting with electrons using a prototype detector of the Sub-Electron-Noise Skipper-CCD Experimental Instrument. The results are based on data taken in the MINOS cavern at the F ermi National Accelerator Laboratory. We focus on data obtained with two distinct readout strategies. For the first strategy, we read out the Skipper-CCD continuously, accumulating an exposure of 0.177 gram-days. While we observe no events containing three or more electrons, we find a large one- and two-electron background event rate, which we attribute to spurious events induced by the amplifier in the Skipper-CCD readout stage. For the second strategy, we take five sets of data in which we switch off all amplifiers while exposing the Skipper-CCD for 120k seconds, and then read out the data through the best prototype amplifier. We find a one-electron event rate of (3.51 +- 0.10) x 10^(-3) events/pixel/day, which is almost two orders of magnitude lower than the one-electron event rate observed in the continuous-readout data, and a two-electron event rate of (3.18 +0.86 -0.55) x 10^(-5) events/pixel/day. We again observe no events containing three or more electrons, for an exposure of 0.069 gram-days. We use these data to derive world-leading constraints on dark matter-electron scattering for masses between 500 keV to 5 MeV, and on dark-photon dark matter being absorbed by electrons for a range of masses below 12.4 eV.
We present the first direct-detection search for eV-to-GeV dark matter using a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch that was optimized for dark-matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electrons, and achieve world-leading sensitivity for a large range of sub-GeV dark matter masses. Data taken with different thicknesses of the detector shield suggest a correlation between the rate of high-energy tracks and the rate of single-electron events previously classified as dark current. We detail key characteristics of the new Skipper-CCDs, which augur well for the planned construction of the ~100-gram SENSEI experiment at SNOLAB.
Traditional direct searches for dark matter, looking for nuclear recoils in deep underground detectors, are challenged by an almost complete loss of sensitivity for light dark matter particles. Consequently, there is a significant effort in the commu nity to devise new methods and experiments to overcome these difficulties, constantly pushing the limits of the lowest dark matter mass that can be probed this way. From a model-building perspective, the scattering of sub-GeV dark matter on nucleons essentially must proceed via new light mediator particles, given that collider searches place extremely stringent bounds on contact-type interactions. Here we present an updated compilation of relevant limits for the case of a scalar mediator, including a new estimate of the near-future sensitivity of the NA62 experiment as well as a detailed evaluation of the model-specific limits from Big Bang nucleosynthesis. We also derive updated and more general limits on DM particles upscattered by cosmic rays, applicable to arbitrary energy- and momentum dependences of the scattering cross section. Finally we stress that dark matter self-interactions, when evaluated beyond the common s-wave approximation, place stringent limits independently of the dark matter production mechanism. These are, for the relevant parameter space, generically comparable to those that apply in the commonly studied freeze-out case. We conclude that the combination of existing (or expected) constraints from accelerators and astrophysics, combined with cosmological requirements, puts robust limits on the maximally possible nuclear scattering rate. In most regions of parameter space these are at least competitive with the best projected limits from currently planned direct detection experiments.
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr CF4) 10 liter detector capable of measuring the vector direction of nuclear recoils with the goal of directional dark matter detection. In this paper we present the first dark matter limit from DMTPC. In an analysis window of 80-200 keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper limit on the spin-dependent WIMP-proton cross section of 2.0 x 10^{-33} cm^{2} for 115 GeV/c^2 dark matter particle mass.
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-rec oil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا