ترغب بنشر مسار تعليمي؟ اضغط هنا

Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC

71   0   0.0 ( 0 )
 نشر من قبل Alissa Monte
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.



قيم البحث

اقرأ أيضاً

The ArDM experiment completed a single-phase commissioning run in 2015 with an active liquid argon target of nearly one tonne in mass. The analysis of the data and comparison to simulations allowed for a test of the crucial detector properties and co nfirmed the low background performance of the setup. The statistical rejection power for electron recoil events using the pulse shape discrimination method was estimated using data from a Cf-252 neutron calibration source. Electron and nuclear recoil band profiles were found to be well described by Gaussian distributions. Employing such a model we derive values for the electron recoil statistical rejection power of more than 10$^8$ in the tonne-scale liquid argon target for events with more than 50 detected photons at a 50% acceptance for nuclear recoils. The Rn-222 emanation rate of the ArDM cryostat at room temperature was found to be 65.6$pm$0.4 $mu$Hz/l, and the Ar-39 specific activity from the employed atmospheric argon to be 0.95$pm$0.05 Bq/kg. The cosmic muon flux at the Canfranc underground site was determined to be between 2 and 3.5$times 10^{-3}m^{2}s^{-1}$ . These results pave the way for the next physics run of ArDM in the double-phase operational mode.
We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data analysis are described. Our results, which are consistent with previous measurements in the region between 100 to 350 V/cm [1] , are systematically higher than the prediction of Atrazhev-Timoshkin[2], and represent the worlds best measurement in the region between 350 to 2000 V/cm. The quantum efficiency of the gold photocathode, the drift velocity and longitudinal diffusion coefficients in gas argon are also presented.
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 h as achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination technique, and the measurement of the residual 39Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.
Proportional electroluminescence (EL) in noble gases has long been used in two-phase detectors for dark matter search, to record ionization signals induced by particle scattering in the noble-gas liquid (S2 signals). Until recently, it was believed t hat proportional electroluminescence was fully due to VUV emission of noble gas excimers produced in atomic collisions with excited atoms, the latter being in turn produced by drifting electrons. In this work we consider an additional mechanism of proportional electroluminescence, namely that of bremsstrahlung of drifting electrons scattered on neutral atoms (so-called neutral bremsstrahlung); it is systemically studied here both theoretically and experimentally. In particular, the absolute EL yield has for the first time been measured in pure gaseous argon in the two-phase mode, using a dedicated two-phase detector with EL gap optically read out by cryogenic PMTs and SiPMs. We show that the neutral bremsstrahlung effect can explain two intriguing observations in EL radiation: that of the substantial contribution of the non-VUV spectral component, extending from the UV to NIR, and that of the photon emission at lower electric fields, below the Ar excitation threshold. Possible applications of neutral bremsstrahlung effect in two-phase dark matter detectors are discussed.
131 - R. Acciarri , C. Adams , J. Asaadi 2013
Electron recombination in highly ionizing stopping protons and deuterons is studied in the ArgoNeuT detector. The data are well modeled by either a Birks model or a modified form of the Box model. The dependence of recombination on the track angle wi th respect to the electric field direction is much weaker than the predictions of the Jaffe columnar theory and by theoretical-computational simulations.