ترغب بنشر مسار تعليمي؟ اضغط هنا

Impact Assessment of Hypothesized Cyberattacks on Interconnected Bulk Power Systems

60   0   0.0 ( 0 )
 نشر من قبل Zhiyuan Yang
 تاريخ النشر 2018
  مجال البحث الهندسة المعلوماتية
والبحث باللغة English




اسأل ChatGPT حول البحث

The first-ever Ukraine cyberattack on power grid has proven its devastation by hacking into their critical cyber assets. With administrative privileges accessing substation networks/local control centers, one intelligent way of coordinated cyberattacks is to execute a series of disruptive switching executions on multiple substations using compromised supervisory control and data acquisition (SCADA) systems. These actions can cause significant impacts to an interconnected power grid. Unlike the previous power blackouts, such high-impact initiating events can aggravate operating conditions, initiating instability that may lead to system-wide cascading failure. A systemic evaluation of nightmare scenarios is highly desirable for asset owners to manage and prioritize the maintenance and investment in protecting their cyberinfrastructure. This survey paper is a conceptual expansion of real-time monitoring, anomaly detection, impact analyses, and mitigation (RAIM) framework that emphasizes on the resulting impacts, both on steady-state and dynamic aspects of power system stability. Hypothetically, we associate the combinatorial analyses of steady state on substations/components outages and dynamics of the sequential switching orders as part of the permutation. The expanded framework includes (1) critical/noncritical combination verification, (2) cascade confirmation, and (3) combination re-evaluation. This paper ends with a discussion of the open issues for metrics and future design pertaining the impact quantification of cyber-related contingencies.



قيم البحث

اقرأ أيضاً

135 - Nima Safari , George Price , 2020
This paper presents lessons learned to date during the Coronavirus Disease 2019 (COVID-19) pandemic from the viewpoint of Saskatchewan power system operations. A load estimation approach is developed to identify how the closures affecting businesses, schools, and other non-critical businesses due to COVID-19 changed the electricity consumption. Furthermore, the impacts of COVID-19 containment measures and re-opening phases on load uncertainty are examined. Changes in CO2 emissions resulting from an increased proportion of renewable energy generation and the change in load pattern are discussed. In addition, the influence of COVID-19 on the balancing authoritys power control performance is investigated. Analyses conducted in the paper are based upon data from SaskPower corporation, which is the principal electric utility in Saskatchewan, Canada. Some recommendations for future power system operation and planning are developed.
Given the increasing penetration in renewable generation, the UK power system is experiencing a decline in system inertia and an increase in frequency response (FR) requirements. Faster FR products are a mitigating solution that can cost-effectively meet the system balancing requirements. Thus, this paper proposes a mixed integer linear programming (MILP) unit commitment model which can simultaneously schedule inertial response, mandatory FR, as well as a sub-second FR product - enhanced frequency response (EFR). The model quantifies the value of providing faster reacting FR products in comparison with other response times from typical FR products. The performance and value of EFR are determined in a series of future energy scenarios with respect to the UK market and system conditions.
Consensusability is an important property for many multi-agent systems (MASs) as it implies the existence of networked controllers driving the states of MAS subsystems to the same value. Consensusability is of interest even when the MAS subsystems ar e physically coupled, which is the case for real-world systems such as power networks. In this paper, we study necessary and sufficient conditions for the consensusability of linear interconnected MASs. These conditions are given in terms of the parameters of the subsystem matrices, as well as the eigenvalues of the physical and communication graph Laplacians. Our results show that weak coupling between subsystems and fast information diffusion rates in the physical and communication graphs favor consensusability. Technical results are verified through computer simulations.
Cyber-physical systems (CPS) are interconnected architectures that employ analog, digital, and communication resources for their interaction with the physical environment. CPS are the backbone of enterprise, industrial, and critical infrastructure. T hus, their vital importance makes them prominent targets for malicious attacks aiming to disrupt their operations. Attacks targeting cyber-physical energy systems (CPES), given their mission-critical nature, can have disastrous consequences. The security of CPES can be enhanced leveraging testbed capabilities to replicate power system operations, discover vulnerabilities, develop security countermeasures, and evaluate grid operation under fault-induced or maliciously constructed scenarios. In this paper, we provide a comprehensive overview of the CPS security landscape with emphasis on CPES. Specifically, we demonstrate a threat modeling methodology to accurately represent the CPS elements, their interdependencies, as well as the possible attack entry points and system vulnerabilities. Leveraging the threat model formulation, we present a CPS framework designed to delineate the hardware, software, and modeling resources required to simulate the CPS and construct high-fidelity models which can be used to evaluate the systems performance under adverse scenarios. The system performance is assessed using scenario-specific metrics, while risk assessment enables system vulnerability prioritization factoring the impact on the system operation. The overarching framework for modeling, simulating, assessing, and mitigating attacks in a CPS is illustrated using four representative attack scenarios targeting CPES. The key objective of this paper is to demonstrate a step-by-step process that can be used to enact in-depth cybersecurity analyses, thus leading to more resilient and secure CPS.
This paper investigates the impact of Kron reduction on the performance of numerical methods applied to the analysis of unbalanced polyphase power systems. Specifically, this paper focuses on power-flow study, state estimation, and voltage stability assessment. For these applications, the standard Newton-Raphson method, linear weighted-least-squares regression, and homotopy continuation method are used, respectively. The performance of the said numerical methods is assessed in a series of simulations, in which the zero-injection nodes of a test system are successively eliminated through Kron reduction.