A Variable-Energy CW Compact Accelerator for Ion Cancer Therapy

59   0   0.0 ( 0 )
 نشر من قبل Johnstone, Carol J.
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English
 تأليف C. Johnstone




اسأل ChatGPT حول البحث

This paper reports on the conclusions of a 2013 Joint DOE/NCI Workshop, and translates clinical accelerator facility requirements into accelerator and beam-delivery technical specifications. Available or feasible accelerator technologies are compared, including a new concept for a compact, CW, and variable energy light ion accelerator currently under development. This new light ion accelerator is based on advances in non-scaling Fixed-Field Alternating gradient (FFAG) accelerator design. The new design concepts combine isochronous orbits with long (up to 4m) straight sections in a compact racetrack format allowing inner circulating orbits to be energy selected for low-loss, CW extraction, effectively eliminating the high-loss energy degrader in conventional CW cyclotron designs.



قيم البحث

اقرأ أيضاً

We report on updates to the accelerator controls for the Neutralized Drift Compression Experiment II, a pulsed induction-type accelerator for heavy ions. The control infrastructure is built around a LabVIEW interface combined with an Apache Cassandra backend for data archiving. Recent upgrades added the storing and retrieving of device settings into the database, as well as ZeroMQ as a message broker that replaces LabVIEWs shared variables. Converting to ZeroMQ also allows easy access via other programming languages, such as Python.
131 - H. X. Q. Norman 2021
Cancer therapy using protons and heavier ions such as carbon has demonstrated advantages over other radiotherapy treatments. To bring about the next generation of clinical facilities, the requirements are likely to reduce the footprint, obtain beam i ntensities above 1E10 particles per spill, and achieve faster extraction for more rapid, flexible treatment. This review follows the technical development of ion therapy, discussing how machine parameters have evolved, as well as trends emerging in technologies for novel treatments such as FLASH. To conclude, the future prospects of ion therapy accelerators are evaluated.
Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure including a matching section between the ion source extraction grids and the RF-acceleration unit. The matching section consist of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture twice the amount of beam and match the beam envelope to conditions for an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.
Front end of a CW linac of the Project X contains an H source, an RFQ, a medium energy transport line with the beam chopper, and a SC low-beta linac that accelerates H- from 2.5 MeV to 160 MeV. SC Single Spoke Resonators (SSR) will be used in the lin ac, because Fermilab already successfully developed and tested a SSR for beta=0.21. Two manufactured cavities achieve 2.5 times more than design accelerating gradients. One of these cavities completely dressed, e.g. welded to helium vessel with integrated slow and fast tuners, and tested in CW regime. Successful tests of beta=0.21 SSR give us a confidence to use this type of cavity for low beta (0.117) and for high-beta (0.4) as well. Both types of these cavities are under development. In present report the basic constrains, parameters, electromagnetic and mechanical design for all the three SSR cavities, and first test results of beta=0.21 SSR are presented.
The treatment of flue gases from power plants and municipal or industrial wastewater using electron beam irradiation technology has been successfully demonstrated in small-scale pilot plants. The beam energy requirement is rather modest, on the order of a few MeV, however the adoption of the technology at an industrial scale requires the availability of high beam power, of the order of 1 MW, in a cost effective way. In this article we present the design of a compact superconducting accelerator capable of delivering a cw electron beam with a current of 1 A and an energy of 1 MeV. The main components are an rf-gridded thermionic gun and a conduction cooled beta= 0.5 elliptical Nb3Sn cavity with dual coaxial power couplers. An engineering and cost analysis shows that the proposed design would result in a processing cost competitive with alternative treatment methods.