ترغب بنشر مسار تعليمي؟ اضغط هنا

Three dimensional Compton scattering tomography

72   0   0.0 ( 0 )
 نشر من قبل James Webber
 تاريخ النشر 2017
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

We propose a new acquisition geometry for electron density reconstruction in three dimensional X-ray Compton imaging using a monochromatic source. This leads us to a new three dimensional inverse problem where we aim to reconstruct a real valued function $f$ (the electron density) from its integrals over spindle tori. We prove injectivity of a generalized spindle torus transform on the set of smooth functions compactly supported on a hollow ball. This is obtained through the explicit inversion of a class of Volterra integral operators, whose solutions give us an expression for the harmonic coefficients of $f$. The polychromatic source case is later considered, and we prove injectivity of a new spindle interior transform, apple transform and apple interior transform on the set of smooth functions compactly supported on a hollow ball. A possible physical model is suggested for both source types. We also provide simulated density reconstructions with varying levels of added pseudo random noise and model the systematic error due to the attenuation of the incoming and scattered rays in our simulation.



قيم البحث

اقرأ أيضاً

Here we present new $L^2$ injectivity results for 2-D and 3-D Compton scattering tomography (CST) problems in translational geometries. The results are proven through the explicit inversion of a new toric section and apple Radon transform, which desc ribe novel 2-D and 3-D acquisition geometries in CST. The geometry considered has potential applications in airport baggage screening and threat detection. We also present a generalization of our injectivity results in 3-D to Radon transforms which describe the integrals of the charge density over the surfaces of revolution of a class of $C^1$ curves.
Here we introduce a new forward model and imaging modality for Bragg Scattering Tomography (BST). The model we propose is based on an X-ray portal scanner with linear detector collimation, currently being developed for use in airport baggage screenin g. The geometry under consideration leads us to a novel two-dimensional inverse problem, where we aim to reconstruct the Bragg scattering differential cross section function from its integrals over a set of symmetric $C^2$ curves in the plane. The integral transform which describes the forward problem in BST is a new type of Radon transform, which we introduce and denote as the Bragg transform. We provide new injectivity results for the Bragg transform here, and describe how the conditions of our theorems can be applied to assist in the machine design of the portal scanner. Further we provide an extension of our results to $n$-dimensions, where a generalization of the Bragg transform is introduced. Here we aim to reconstruct a real valued function on $mathbb{R}^{n+1}$ from its integrals over $n$-dimensional surfaces of revolution of $C^2$ curves embedded in $mathbb{R}^{n+1}$. Injectivity proofs are provided also for the generalized Bragg transform.
Here we present a novel microlocal analysis of a new toric section transform which describes a two dimensional image reconstruction problem in Compton scattering tomography and airport baggage screening. By an analysis of two separate limited data pr oblems for the circle transform and using microlocal analysis, we show that the canonical relation of the toric section transform is 2--1. This implies that there are image artefacts in the filtered backprojection reconstruction. We provide explicit expressions for the expected artefacts and demonstrate these by simulations. In addition, we prove injectivity of the forward operator for $L^infty$ functions supported inside the open unit ball. We present reconstructions from simulated data using a discrete approach and several regularizers with varying levels of added pseudo-random noise.
126 - James Webber 2015
We lay the foundations for a new fast method to reconstruct the electron density in x-ray scanning applications using measurements in the dark field. This approach is applied to a type of machine configuration with fixed energy sensitive (or resolvin g) detectors, and where the X-ray source is polychromatic. We consider the case where the measurements in the dark field are dominated by the Compton scattering process. This leads us to a 2D inverse problem where we aim to reconstruct an electron density slice from its integrals over discs whose boundaries intersect the given source point. We show that a unique solution exists for smooth densities compactly supported on an annulus centred at the source point. Using Sobolev space estimates we determine a measure for the ill posedness of our problem based on the criterion given by Natterer (The mathematics of computerized tomography SIAM 2001). In addition, with a combination of our method and the more common attenuation coefficient reconstruction, we show under certain assumptions that the atomic number of the target is uniquely determined. We test our method on simulated data sets with varying levels of added pseudo random noise.
Here we present a novel microlocal analysis of generalized Radon transforms which describe the integrals of $L^2$ functions of compact support over surfaces of revolution of $C^{infty}$ curves $q$. We show that the Radon transforms are elliptic Fouri er Integral Operators (FIO) and provide an analysis of the left projections $Pi_L$. Our main theorem shows that $Pi_L$ satisfies the semi-global Bolker assumption if and only if $g=q/q$ is an immersion. An analysis of the visible singularities is presented, after which we derive novel Sobolev smoothness estimates for the Radon FIO. Our theory has specific applications of interest in Compton Scattering Tomography (CST) and Bragg Scattering Tomography (BST). We show that the CST and BST integration curves satisfy the Bolker assumption and provide simulated reconstructions from CST and BST data. Additionally we give example sinusoidal integration curves which do not satisfy Bolker and provide simulations of the image artefacts. The observed artefacts in reconstruction are shown to align exactly with our predictions.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا