ترغب بنشر مسار تعليمي؟ اضغط هنا

A new technique for infrared scintillation measurements

319   0   0.0 ( 0 )
 نشر من قبل Federico Chiossi
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We propose a new technique to measure the infrared scintillation light yield of rare earth (RE) doped crystals by comparing it to near UV-visible scintillation of a calibrated Pr:(Lu$_{0.75}$Y$_{0.25}$)$_{3}$Al$_5$O$_{12}$ sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to SI{1700}{nm} of this crystal.



قيم البحث

اقرأ أيضاً

142 - Ettore Segreto 2011
A simple model for the estimation of the light yield of a scintillation detector is developed under general assumptions and relying exclusively on the knowledge of its optical properties. The model allows to easily incorporate effects related to Rayl eigh scattering and absorption of the photons.The predictions of the model are benchmarked with the outcomes of Monte Carlo simulations of specific scintillation detectors. An accuracy at the level of few percent is achieved. The case of a real liquid argon based detector is explicitly treated and the predicted light yield is compared with the measured value.
The digital signal processing has greatly simplified the process of phase noise measurements, especially in oscillators, but its applications are largely confined to the frequencies below 400 MHz. We propose a novel transpose frequency technique, whi ch extends the frequency range of digital noise measurements to the microwave domain and beyond. We discuss two basic variations of the proposed noise measurement technique, one of which enables characterization of phase fluctuations added to the passing signal by the particular microwave component, for example by an amplifier, while another one is intended for measurements of phase fluctuations of the incoming signal itself.
123 - Xi Yuan , Xing Zhang , Xufei Xie 2013
A neutron detector based on EJ301 liquid scintillator has been employed at EAST to measure the neutron energy spectrum for D-D fusion plasma. The detector was carefully characterized in different quasi-monoenergetic neutron fields generated by a 4.5 MV Van de Graaff accelerator. In recent experimental campaigns, due to the low neutron yield at EAST, a new shielding device was designed and located as close as possible to the tokamak to enhance the count rate of the spectrometer. The fluence of neutrons and gamma-rays was measured with the liquid neutron spectrometer and was consistent with 3He proportional counter and NaI (Tl) gamma-ray spectrometer measurements. Plasma ion temperature values were deduced from the neutron spectrum in discharges with lower hybrid wave injection and ion cyclotron resonance heating. Scattered neutron spectra were simulated by the Monte Carlo transport Code, and they were well verified by the pulse height measurements at low energies.
Europe monitors transits using radiation detectors to prevent illicit trafficking of nuclear materials. The SCINTILLA project aims to develop a toolbox of innovative technologies designed to address different usage cases. This article will review the scope, approach, results of the first benchmark campaign and future plans of the SCINTILLA project.
Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $times$ 50 $times$ 3$^{t}$ mm$^3 $ and 80 $times$ 100 $times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energy and position responses are measured with $^{18}$O primary beam at 400 MeV/nucleon. After the off-line walk-effect and position corrections, the time resolution of the two detectors are determined to be 27 ps ($sigma$) and 36 ps ($sigma$), respectively. Both detectors have nearly the same energy resolution of 3$%$ ($sigma$) and position resolution of 2 mm ($sigma$). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا