ترغب بنشر مسار تعليمي؟ اضغط هنا

High-resolution, high-sensitivity, ground-based solar spectropolarimetry with a new fast imaging polarimeter

213   0   0.0 ( 0 )
 نشر من قبل Francisco A. Iglesias
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Context. Remote sensing of weak and small-scale solar magnetic fields is of utmost relevance for a number of important open questions in solar physics. This requires the acquisition of spectropolarimetric data with high spatial resolution (0.1 arcsec) and low noise (1e-3 to 1e-5 of the continuum intensity). The main limitations to obtain these measurements from the ground, are the degradation of the image resolution produced by atmospheric seeing and the seeing-induced crosstalk (SIC). Aims. We introduce the prototype of the Fast Solar Polarimeter (FSP), a new ground-based, high-cadence polarimeter that tackles the above-mentioned limitations by producing data that are optimally suited for the application of post-facto image restoration, and by operating at a modulation frequency of 100 Hz to reduce SIC. Results. The pnCCD camera reaches 400 fps while keeping a high duty cycle (98.6 %) and very low noise (4.94 erms). The modulator is optimized to have high (> 80%) total polarimetric efficiency in the visible spectral range. This allows FSP to acquire 100 photon-noise-limited, full-Stokes measurements per second. We found that the seeing induced signals present in narrow-band, non-modulated, quiet-sun measurements are (a) lower than the noise (7e-5) after integrating 7.66 min, (b) lower than the noise (2.3e-4) after integrating 1.16 min and (c) slightly above the noise (4e-3) after restoring case (b) by means of a multi-object multi-frame blind deconvolution. In addition, we demonstrate that by using only narrow-band images (with low SNR of 13.9) of an active region, we can obtain one complete set of high-quality restored measurements about every 2 s.



قيم البحث

اقرأ أيضاً

536 - Zhong Liu , Jun Xu , Bo-Zhong Gu 2014
The New Vacuum Solar Telescope (NVST) is a 1 meter vacuum solar telescope that aims to observe the fine structures on the Sun. The main tasks of NVST are high resolution imaging and spectral observations, including the measurements of solar magnetic field. NVST is the primary ground-based facility of Chinese solar community in this solar cycle. It is located by the Fuxian Lake of southwest China, where the seeing is good enough to perform high resolution observations. In this paper, we first introduce the general conditions of Fuxian Solar Observatory and the primary science cases of NVST. Then, the basic structures of this telescope and instruments are described in detail. Finally, some typical high resolution data of solar photosphere and chromosphere are also shown.
This paper describes the development of X-ray diffractive optics for imaging solar flares with better than 0.1 arcsec angular resolution. X-ray images with this resolution of the geq10 MK plasma in solar active regions and solar flares would allow th e cross-sectional area of magnetic loops to be resolved and the coronal flare energy release region itself to be probed. The objective of this work is to obtain X-ray images in the iron-line complex at 6.7 keV observed during solar flares with an angular resolution as fine as 0.1 arcsec - over an order of magnitude finer than is now possible. This line emission is from highly ionized iron atoms, primarily Fe xxv, in the hottest flare plasma at temperatures in excess of approx10 MK. It provides information on the flare morphology, the iron abundance, and the distribution of the hot plasma. Studying how this plasma is heated to such high temperatures in such short times during solar flares is of critical importance in understanding these powerful transient events, one of the major objectives of solar physics. We describe the design, fabrication, and testing of phase zone plate X-ray lenses with focal lengths of approx100 m at these energies that would be capable of achieving these objectives. We show how such lenses could be included on a two-spacecraft formation-flying mission with the lenses on the spacecraft closest to the Sun and an X-ray imaging array on the second spacecraft in the focal plane approx100 m away. High resolution X-ray images could be obtained when the two spacecraft are aligned with the region of interest on the Sun. Requirements and constraints for the control of the two spacecraft are discussed together with the overall feasibility of such a formation-flying mission.
Lucky Imaging combined with a low order adaptive optics system has given the highest resolution images ever taken in the visible or near infrared of faint astronomical objects. This paper describes a new instrument that has already been deployed on t he WHT 4.2m telescope on La Palma, with particular emphasis on the optical design and the predicted system performance. A new design of low order wavefront sensor using photon counting CCD detectors and multi-plane curvature wavefront sensor will allow virtually full sky coverage with faint natural guide stars. With a 2 x 2 array of 1024 x 1024 photon counting EMCCDs, AOLI is the first of the new class of high sensitivity, near diffraction limited imaging systems giving higher resolution in the visible from the ground than hitherto been possible from space.
We describe the High-Precision Polarimetric Instrument-2 (HIPPI-2) a highly versatile stellar polarimeter developed at the University of New South Wales (UNSW). Two copies of HIPPI-2 have been built and used on the 60-cm telescope at Western Sydney U niversitys (WSU) Penrith Observatory, the 8.1-m Gemini North Telescope at Mauna Kea and extensively on the 3.9-m Anglo-Australian Telescope (AAT). The precision of polarimetry, measured from repeat observations of bright stars in the SDSS g band, is better than 3.5 ppm (parts per million) on the 3.9-m AAT and better than 11 ppm on the 60-cm WSU telescope. The precision is better at redder wavelengths and poorer in the blue. On the Gemini North 8-m telescope the performance is limited by a very large and strongly wavelength dependent telescope polarization that reached 1000s of ppm at blue wavelengths and is much larger than we have seen on any other telescope.
59 - Craig Mackay 2019
Astronomers working with faint targets will benefit greatly from improved image quality on current and planned ground-based telescopes. At present, most adaptive optic systems are targeted at the highest resolution with bright guide stars. We demonst rate a significantly new approach to measuring low-order wavefront errors by using a pupil-plane curvature wavefront sensor design. By making low order wavefront corrections we can deliver significant improvements in image resolution in the visible on telescopes in the 2.5m to 8.2m range on good astronomical sites. As a minimum the angular resolution will be improved by a factor of 2.5 to 3 under any reasonable conditions and, with further correction and image selection, even sharper images may be obtained routinely. We re-examine many of the assumptions about what may be achieved with faint reference stars to achieve this performance. We show how our new design of curvature wavefront sensor combined with wavefront fitting routines based on radon transforms allow this performance to be achieved routinely. Simulations over a wide range of conditions match the performance already achieved in runs with earli
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا