A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high significance event-by-event discrimination between alpha and beta/gamma interactions at the $^{130}$Te neutrino-less double beta decay Q-value - (2527.515 $pm$ 0.013) keV - has been demonstrated. This measurement opens the possibility of drastically reducing the background in cryogenic experiments based on TeO$_{2}$.
Next generation calorimetric experiments for the search of rare events rely on the detection of tiny amounts of light (of the order of 20 optical photons) to discriminate and reduce background sources and improve sensitivity. Calorimetric detectors a
re the simplest solution for photon detection at cryogenic (mK) temperatures. The development of silicon based light detectors with enhanced performance thanks to the use of the Neganov-Luke effect is described. The aim of this research line is the production of high performance detectors with industrial-grade reproducibility and reliability.
Random coincidences of nuclear events can be one of the main background sources in low-temperature calorimetric experiments looking for neutrinoless double-beta decay, especially in those searches based on scintillating bolometers embedding the promi
sing double-beta candidate $^{100}$Mo, because of the relatively short half-life of the two-neutrino double-beta decay of this nucleus. We show in this work that randomly coinciding events of the two-neutrino double decay of $^{100}$Mo in enriched Li$_2$$^{100}$MoO$_4$ detectors can be effectively discriminated by pulse-shape analysis in the light channel if the scintillating bolometer is provided with a Neganov-Luke light detector, which can improve the signal-to-noise ratio by a large factor, assumed here at the level of $sim 750$ on the basis of preliminary experimental results obtained with these devices. The achieved pile-up rejection efficiency results in a very low contribution, of the order of $sim 6times10^{-5}$ counts/(keV$cdot$kg$cdot$y), to the background counting rate in the region of interest for a large volume ($sim 90$ cm$^3$) Li$_2$$^{100}$MoO$_4$ detector. This background level is very encouraging in view of a possible use of the Li$_2$$^{100}$MoO$_4$ solution for a bolometric tonne-scale next-generation experiment as that proposed in the CUPID project.
We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting res
ults in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, and (3) it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath. We tested this new technique with a 16 cm$^2$ Ge light detector with thermistor readout sitting on the surface of a large TeO$_2$ bolometer. The light collection efficiency was increased by greater than 50% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20~eV RMS that, together with increased light collection, enabled us to obtain the best $alpha$ vs $beta/gamma$ discrimination ever obtained with massive TeO$_2$ crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE.
A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a dep
leted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the DE-E technique or Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the DE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector whose doping uniformity is not good enough for isotopic identification at full depletion.
In the present work, we describe the results obtained with a large ($approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0 ubetabeta$) of $^{130}$Te. We demonstrate an efficient $alpha$ particle discrim
ination (99.9%) with a high acceptance of the $0 ubetabeta$ signal (about 96%), expected at $approx 2.5$ MeV. This unprecedented result was possible thanks to the superior performance (10 eV rms baseline noise) of a Neganov-Luke-assisted germanium bolometer used to detect a tiny (70 eV) light signal from the TeO$_2$ detector, dominated by $gamma$($beta$)-induced Cherenkov radiation but exhibiting also a clear scintillation component. The obtained results represent a major breakthrough towards the TeO$_2$-based version of CUORE Upgrade with Particle IDentification (CUPID), a ton-scale cryogenic $0 ubetabeta$ experiment proposed as a follow-up to the CUORE project with particle identification. The CUORE experiment began recently a search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 125-cm$^3$ TeO$_2$ bolometers. The lack of $alpha$ discrimination in CUORE makes $alpha$ decays at the detector surface the dominant background component, at the level of $approx 0.01$ counts/(keV kg y) in the region of interest. We show here, for the first time with a CUORE-size bolometer and using the same technology as CUORE for the readout of both heat and light signals, that surface $alpha$ background can be fully rejected.