ترغب بنشر مسار تعليمي؟ اضغط هنا

Performance of Silicon immersed gratings: Measurement, analysis and modelling

91   0   0.0 ( 0 )
 نشر من قبل Michiel Rodenhuis
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The use of Immersed Gratings offers advantages for both space- and ground-based spectrographs. As diffraction takes place inside the high-index medium, the optical path difference and angular dispersion are boosted proportionally, thereby allowing a smaller grating area and a smaller spectrometer size. Short-wave infrared (SWIR) spectroscopy is used in space-based monitoring of greenhouse and pollution gases in the Earth atmosphere. On the extremely large telescopes currently under development, mid-infrared high-resolution spectrographs will, among other things, be used to characterize exo-planet atmospheres. At infrared wavelengths, Silicon is transparent. This means that production methods used in the semiconductor industry can be applied to the fabrication of immersed gratings. Using such methods, we have designed and built immersed gratings for both space- and ground-based instruments, examples being the TROPOMI instrument for the European Space Agency Sentinel-5 precursor mission, Sentinel-5 (ESA) and the METIS (Mid-infrared E-ELT Imager and Spectrograph) instrument for the European Extremely Large Telescope. Three key parameters govern the performance of such gratings: The efficiency, the level of scattered light and the wavefront error induced. In this paper we describe how we can optimize these parameters during the design and manufacturing phase. We focus on the tools and methods used to measure the actual performance realized and present the results. In this paper, the bread-board model (BBM) immersed grating developed for the SWIR-1 channel of Sentinel-5 is used to illustrate this process. Stringent requirements were specified for this grating for the three performance criteria. We will show that -with some margin- the performance requirements have all been met.



قيم البحث

اقرأ أيضاً

In the present paper we demonstrate the approach of using a holographic grating on a freeform surface for advanced spectrographs design. We discuss the surface and groove pattern description used for ray-tracing. Moreover, we present a general proced ure of diffraction efficiency calculation, which accounts for the change of hologram recording and operation conditions across the surface. The primary application of this approach is the optical design of the POLLUX spectropolarimeter for the LUVOR mission project where a freeform holographic grating operates simultaneously as a cross-disperser and a camera with high resolution and high dispersion. The medium ultraviolet channel design of POLLUX is considered in detail as an example. Its resolving power reaches [126,000-133,000] in the region of 118.5-195 nm. Also, we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 4000 in the region 350-550 nm and remains stable along the slit.
Silicon immersion gratings and grisms enable compact, near-infrared spectrographs with high throughput. These instruments find use in ground-based efforts to characterize stellar and exoplanet atmospheres, and in space-based observatories. Our gratin g fabrication technique uses x-ray crystallography to orient silicon parts prior to cutting, followed by lithography and wet chemical etching to produce the blaze. This process takes advantage of the crystal structure and relative difference in etching rates between the (100) and (111) planes such that we can produce parts that have surface errors < {lambda}/4. Previous measurements indicate that chemical etching can yield a final etched blaze that slightly differs from the orientation of the (111) plane. This difference can be corrected by the mechanical mount in the case of the immersion gratings, but doing so may compromise grating throughput due to shadowing. In the case of the grisms, failure to take the actual blaze into account will reduce the brightness of the undeviated ray. We report on multiple techniques to precisely measure the blaze of our in-house fabricated immersion gratings. The first method uses a scanning electron microscope to image the blaze profile, which yields a measurement precision of 0.5 degrees. The second method is an optical method of measuring the angle between blaze faces using a rotation stage, which yields a measurement precision of 0.2 degrees. Finally, we describe a theoretical blaze function modeling method, which we expect to yield a measurement precision of 0.1 degrees. With these methods, we can quantify the accuracy with which the wet etching produces the required blaze and further optimize grating and grism efficiencies.
The MCAO Assisted Visible Imager and Spectrograph (MAVIS) Adaptive Optics Module has very demanding goals to support science in the optical: providing 15% SR in V band on a large FoV of 30arcsec diameter in standard atmospheric conditions at Paranal. It will be able to work in closed loop on up to three natural guide stars down to H=19, providing a sky coverage larger than 50% in the south galactic pole. Such goals and the exploration of a large MCAO system parameters space have required a combination of analytical and end- to-end simulations to assess performance, sky coverage and drive the design. In this work we report baseline performance, statistical sky coverage and parameters sensitivity analysis done in the phase-A instrument study.
High-resolution ($R = lambda /Delta lambda > 2000$) x-ray absorption and emission line spectroscopy in the soft x-ray band is a crucial diagnostic for the exploration of the properties of ubiquitous warm and hot plasmas and their dynamics in the cosm ic web, galaxy clusters, galaxy halos, intragalactic space, and star atmospheres. Soft x-ray grating spectroscopy with $R > 10{,}000$ has been demonstrated with critical-angle transmission (CAT) gratings. CAT gratings combine the relaxed alignment and temperature tolerances and low mass of transmission gratings with high diffraction efficiency blazed in high orders. They are an enabling technology for the proposed Arcus grating explorer and were selected for the Lynx design reference mission grating spectrometer instrument. Both Arcus and Lynx require the manufacture of hundreds to perhaps $approx 2000$ large-area CAT gratings. We are developing new patterning and fabrication process sequences that are conducive to large-format volume processing on state-of-the-art 200 mm wafer tools. Recent x-ray tests on 200 nm-period gratings patterned using e-beam-written masks and 4x projection lithography in conjunction with silicon pore focusing optics demonstrated $R approx 10^4$ at 1.49 keV. Extending the grating depth from 4 $mu$m to 6 $mu$m is predicted to lead to significant improvements in diffraction efficiency and is part of our current efforts using a combination of deep reactive-ion etching and wet etching in KOH solution. We describe our recent progress in grating fabrication and report our latest diffraction efficiency and modeling results.
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientif ic goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy. DAMPE consists of four sub-detectors: a plastic scintillator strip detector, a Silicon-Tungsten tracKer-converter (STK), a BGO calorimeter and a neutron detector. The STK is composed of six double layers of single-sided silicon micro-strip detectors interleaved with three layers of tungsten for photon
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا