ترغب بنشر مسار تعليمي؟ اضغط هنا

DAFNE and KLOE-2

165   0   0.0 ( 0 )
 نشر من قبل Antonio De Santis
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English
 تأليف A. De Santis




اسأل ChatGPT حول البحث

The DAFNE collider, located in the Frascati National Laboratories of INFN, has two main rings, where electrons and positrons are stored to collide at a center of mass energy of 1.02 GeV, the phi resonance mass. KLOE-2 experiment is located at the collider interaction region. The detector is capable to observe and collect data coming from phi decay: charged and neutral kaon pairs, lighter unflavored mesons (eta, eta, f0, a0, omega/rho). In the first half of 2013 the KLOE detector has been upgraded inserting new detector layers in the inner part of the apparatus, around the interaction region in order to improve detector hermeticity and acceptance. The long shutdown has been used to undertake a general consolidation program aimed at improving the DAFNE performances. This contribution presents the phi-factory setup and the achieved performances in terms of beam currents, luminosity and related aspects together with the KLOE-2 physics program, upgrade status report and recent physics results.



قيم البحث

اقرأ أيضاً

The upgrade of the DA$Phi$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE$^2$ thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstru ction of $K_Lto 2pi^0$ events with photons hitting the quadrupoles, a tile calorimeter, QCALT, with high efficiency to low energy photons (20-300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. We propose a tile calorimeter with a high granularity readout corresponding to about 2500 silicon photomultipliers (SiPM) of $1times 1$ mm$^2$ area. Moreover, the low polar angle regions need the realization of a dense crystal calorimeter with very high time resolution performances to extend the acceptance for multiphotons events. Best candidates for this calorimeter are LYSO crystals with APD readout or PbWO$_4$ crystals with large area SIPM readout.
In order to fully reconstruct to the reaction e+e- to e+e- gamma-gamma in the energy region of the phi meson production, new detectors along the DAFNE beam line have to be installed in order to detect the scattered e+e-. The High Energy Tagger (HET) detector measures the deviation of leptons from their main orbit by determining their position and timing so to tag gamma-gamma physics events and disentangle them from background. The HET detectors are placed at the exit of the DAFNE dipole magnets, 11 m away from the IP, both on positron and electron lines. The HET sensitive area is made up of a set of 28 plastic scintillators. A dedicated DAQ electronics board based on a Xilinx Virtex-5 FPGA have been developed for this detector. It provides a MultiHit TDC with a time resolution of the order of 500 ps and the possibility to acquire data any 2.5 ns, thus allowing to clearly identify the correct bunch crossing. First results of the commissioning run are presented.
The upgrade of the DA$Phi$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE-2 thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstruct ion of $K_Lto 2pi^0$ events with photons hitting the quadrupoles a calorimeter with high efficiency to low energy photons (20-300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. To match these requirements, we are designing a tile calorimeter, QCALT, where each single tile is readout by mean of SiPM for a total granularity of 2400 channels. We show first tests of the different calorimeter components.
88 - M. Silarski 2016
The KLOE-2 experiment at the INFN Laboratori Nazionali di Frascati (LNF) is currently taking data at the upgraded $e^{+}e^{-}$ DAFNE collider. Present Run II follows a~development phase to assess the feasibility of a long term acquisition program, Ru n I, which successfully ended in July 2015 with 1 fb$^{-1}$ integrated luminosity collected in less than eight months. KLOE-2 represents the continuation of the KLOE experiment with a new physics program. The KLOE detector has undergone several upgrades including state-of-the-art cylindrical GEM Inner Tracker, electron-positron taggers for the $gammagamma$-physics studies and new calorimeters around the interaction point. In this article we briefly present the overview of the KLOE-2 experiment including the present status and achievements together with the physics plans.
The KLOE experiment at the upgraded DAFNE e+e- collider in Frascati (KLOE-2) is going to start a new data taking at the beginning of 2010 with its detector upgraded with a tagging system for the identification of gamma-gamma interactions. The tagging stations for low-energy e+e- will consist in two calorimeters The calorimeter used to detect low-energy e+e- will be placed between the beam-pipe outer support structure and the inner wall of the KLOE drift chamber. This calorimeter will be made of LYSO crystals readout by Silicon Photomultipliers, to achieve an energy resolution better than 8% at 200 MeV.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا