In order to fully reconstruct the gamma gamma processes (e+e- -> e+e- gamma gamma) in the energy region of the phi meson production, new detectors along the DAFNE beam line have been installed in order to detect the scattered e+e-.



قيم البحث

اقرأ أيضاً

Three new sub-detectors have been installed on May 2013 in the KLOE apparatus of Laboratori Nazionali di Frascati of INFN. Photon detection is improved by means of a small crystal calorimeter, named CCALT, in the very forward direction and of a tungs ten-scintillating tile sampling device, named QCALT, instrumenting the low-beta quadrupoles of the accelerator. During the first DA$phi$NE operations, some preliminary runs, both with and without collisions, have been acquired allowing the commissioning of new subdetectors. In this paper, we report a brief description of QCALT and CCALT and a summary of the commissioning phase.
The KLOE experiment at the upgraded DAFNE e+e- collider in Frascati (KLOE-2) is going to start a new data taking at the beginning of 2010 with its detector upgraded with a tagging system for the identification of gamma-gamma interactions. The tagging stations for low-energy e+e- will consist in two calorimeters The calorimeter used to detect low-energy e+e- will be placed between the beam-pipe outer support structure and the inner wall of the KLOE drift chamber. This calorimeter will be made of LYSO crystals readout by Silicon Photomultipliers, to achieve an energy resolution better than 8% at 200 MeV.
The upgrade of the DA$Phi$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE$^2$ thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstru ction of $K_Lto 2pi^0$ events with photons hitting the quadrupoles, a tile calorimeter, QCALT, with high efficiency to low energy photons (20-300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. We propose a tile calorimeter with a high granularity readout corresponding to about 2500 silicon photomultipliers (SiPM) of $1times 1$ mm$^2$ area. Moreover, the low polar angle regions need the realization of a dense crystal calorimeter with very high time resolution performances to extend the acceptance for multiphotons events. Best candidates for this calorimeter are LYSO crystals with APD readout or PbWO$_4$ crystals with large area SIPM readout.
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical de sign report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.