ترغب بنشر مسار تعليمي؟ اضغط هنا

Beam breakup simulation study for high energy ERL

379   0   0.0 ( 0 )
 نشر من قبل Si Chen
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The maximum beam current can be accelerated in an Energy Recovery Linac (ERL) can be severely limited by the transverse multi-pass beam breakup instability (BBU), especially in future ERL light sources with multi-GeV high energy beam energy and more than 100 mA average current. In this paper, the multi-pass BBU of such a high energy ERL is studied based on the simulation on a 3-GeV ERL light source proposed by KEK. It is expected to provide a reference to the future high energy ERL projects by this work.



قيم البحث

اقرأ أيضاً

The ELIMED (MEDical and multidisciplinary application at ELI Beamlines) beam line is being developed at INFN-LNS with the aim of transporting and selecting in energy proton and ion beams accelerated by laser-matter interaction at ELI Beamlines in Pra gue. It will be a section of the ELIMAIA (ELI Multidisciplinary Applications of laser-Ions Acceleration) beam line, dedicated to applications, including the medical one, of laser-accelerated ion beams [1,2]. A Monte Carlo model has been developed to support the design of the beam line in terms of particle transport efficiency, to optimize the transport parameters at the irradiation point in air and, furthermore, to predict beam parameters in order to deliver dose distributions of clinical relevance. The application has been developed using the Geant4 [3] Monte Carlo toolkit and has been designed in a modular way in order to easily switch on/off geometrical components according to different experimental setups and users requirements, as reported in [4], describing the early-stage code and simulations. The application has been delivered to ELI Beamlines and will be available for future ELIMAIAs users as ready-to-use tool useful during experiment preparation and analysis. The final version of the developed application will be described in detail in this contribution, together with the final results, in terms of energy spectra and transmission efficiency along the in-vacuum beam line, obtained by performing end-to-end simulations.
A special beam line for high energy electron radiography is designed, including achromat and imaging systems. The requirement of the angle and position correction on the target from imaging system can be approximately realized by fine tuning the quad rupoles used in the achromat. The imaging system is designed by fully considering the limitation from the laboratory and beam diagnostics devices space. Two kinds of imaging system are designed and both show a good performance of imaging by beam trajectory simulation. The details of the beam optical requirement and optimization design are presented here. The beam line is designed and prepared to install in Tsinghua university linear electron accelerator laboratory for further precise electron radiography experiment study.
90 - S. Glukhov 2021
MESA (Mainz Energy recovery Superconducting Accelerator) is an energy recovery linac (ERL) which is under construction at Johannes Gutenberg University in Mainz. It will be operated in external beam (EB) mode with 150 $mu$A electron beam at 155 MeV a nd energy recovery (ER) mode with 1 mA (first stage) and later 10 mA (second stage) electron beam at 105 MeV. An important factor which may limit performance of the machine is a beam breakup (BBU) instability which may occur due to excitation of higher-order modes (HOMs) in superconducting RF cavities. This effect occurs only when the injected beam current exceeds a threshold value. The aim of the present work is to develop a software for reliable determination of the threshold current in MESA, find main factors which may change its value and finally make a decision concerning capability of MESA operation at 10 mA and need for additional measures for suppressing BBU instability.
250 - E. Recepoglu , S. Sultansoy 2009
A high luminosity energy recovery linac on ring type electron-positron collider operating as super charm factory is proposed. It is shown that the luminosity L=2.3 10^35 cm^-2s^-1 can be achieved for center of mass energy 3.77 GeV. The physics goals of this machine in investigation for charmed particles properties are briefly discussed.
A new system used for monitoring energetic Coulomb-scattered electrons as the main diagnostic for accurately aligning the electron and ion beams in the new Relativistic Heavy Ion Collider (RHIC) electron lenses is described in detail. The theory of e lectron scattering from relativistic ions is developed and applied to the design and implementation of the system used to achieve and maintain the alignment. Commissioning with gold and 3He beams is then described as well as the successful utilization of the new system during the 2015 RHIC polarized proton run. Systematic errors of the new method are then estimated. Finally, some possible future applications of Coulomb-scattered electrons for beam diagnostics are briefly discussed.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا