Anomalous heating of trapped atomic ions is a major obstacle to their use as quantum bits in a scalable quantum computer. The physical origin of this heating is not fully understood, but experimental evidence suggests that it is caused by electric-field noise emanating from the surface of the trap electrodes. In this study, we have investigated the role that adsorbates on the electrodes play by identifying contaminant overlayers, developing an in situ argon-ion beam cleaning procedure, and measuring ion heating rates before and after cleaning the trap electrodes surfaces. We find a reduction of two orders of magnitude in heating rate after cleaning.



قيم البحث

اقرأ أيضاً

Anomalous motional heating is a major obstacle to scalable quantum information processing with trapped ions. While the source of this heating is not yet understood, several previous studies suggest that surface contaminants may be largely responsible . We demonstrate an improvement by a factor of four in the room-temperature heating rate of a niobium surface electrode trap by in situ plasma cleaning of the trap surface. This surface treatment was performed with a simple homebuilt coil assembly and commercially-available matching network and is considerably gentler than other treatments, such as ion milling or laser cleaning, that have previously been shown to improve ion heating rates. We do not see an improvement in the heating rate when the trap is operated at cryogenic temperatures, pointing to a role of thermally-activated surface contaminants in motional heating whose activity may freeze out at low temperatures.
Laser-cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355nm. The effect of the laser pulses at several energy density levels has been tested by measuring the heating r ate of a single 40Ca+ trapped ion as a function of its secular frequency. A reduction of the electric-field noise spectral density by ~50% has been observed and a change in the frequency dependence also noticed. This is the first reported experiment where the anomalous heating phenomenon has been reduced by removing the source as opposed to reducing its thermal driving by cryogenic cooling. This technique may open the way to better control of the electrode surface quality in ion microtraps.
Non-thermal pickup ions (PUIs) are created in the solar wind (SW) by charge-exchange between SW ions (SWIs) and slow interstellar neutral atoms. It has long been theorized, but not directly observed, that PUIs should be preferentially heated at quasi -perpendicular shocks compared to thermal SWIs. We present in situ observations of interstellar hydrogen (H+) PUIs at an interplanetary shock by the New Horizons Solar Wind Around Pluto (SWAP) instrument at ~34 au from the Sun. At this shock, H+ PUIs are only a few percent of the total proton density but contain most of the internal particle pressure. A gradual reduction in SW flow speed and simultaneous heating of H+ SWIs is observed ahead of the shock, suggesting an upstream energetic particle pressure gradient. H+ SWIs lose ~85% of their energy flux across the shock and H+ PUIs are preferentially heated. Moreover, a PUI tail is observed downstream of the shock, such that the energy flux of all H+ PUIs is approximately six times that of H+ SWIs. We find that H+ PUIs, including their suprathermal tail, contain almost half of the total downstream energy flux in the shock frame.
139 - G. Shu , G. Vittorini , C. Volin 2014
We measure ion heating following transport throughout a Y-junction surface-electrode ion trap. By carefully selecting the trap voltage update rate during adiabatic transport along a trap arm, we observe minimal heating relative to the anomalous heati ng background. Transport through the junction results in an induced heating between 37 and 150 quanta in the axial direction per traverse. To reliably measure heating in this range, we compare the experimental sideband envelope, including up to fourth-order sidebands, to a theoretical model. The sideband envelope method allows us to cover the intermediate heating range inaccessible to the first-order sideband and Doppler recooling methods. We conclude that quantum information processing in this ion trap will likely require sympathetic cooling in order to support high fidelity gates after junction transport.
107 - M.Duncan , J.Links , G.J.Milburn 2007
Iterated dynamical maps offer an ideal setting to investigate quantum dynamical bifurcations and are well adapted to few-qubit quantum computer realisations. We show that a single trapped ion, subject to periodic impulsive forces, exhibits a rich str ucture of dynamical bifurcations derived from the Jahn-Teller Hamiltonian flow model. We show that the entanglement between the oscillator and electronic degrees of freedom reflects the underlying dynamical bifurcation in a Floquet eigenstate.