ﻻ يوجد ملخص باللغة العربية
We present an iterative scheme designed to recover calibrated I, Q, and U maps from Planck-HFI data using the orbital dipole due to the satellite motion with respect to the Solar System frame. It combines a map reconstruction, based on a destriping technique, juxtaposed with an absolute calibration algorithm. We evaluate systematic and statistical uncertainties incurred during both these steps with the help of realistic, Planck-like simulations containing CMB, foreground components and instrumental noise, and assess the accuracy of the sky map reconstruction by considering the maps of the residuals and their spectra. In particular, we discuss destriping residuals for polarization sensitive detectors similar to those of Planck-HFI under different noise hypotheses and show that these residuals are negligible (for intensity maps) or smaller than the white noise level (for Q and U Stokes maps), for l > 50. We also demonstrate that the combined level of residuals of this scheme remains comparable to those of the destriping-only case except at very low l where residuals from the calibration appear. For all the considered noise hypotheses, the relative calibration precision is on the order of a few 10e-4, with a systematic bias of the same order of magnitude.
This paper describes the processing applied to the HFI cleaned time-ordered data to produce photometrically calibrated maps. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To get the best accuracy on the calibration on s
Future cosmic microwave background (CMB) polarisation experiments aim to measure an unprecedentedly small signal - the primordial gravity wave component of the polarisation field B-mode. To achieve this, they will analyse huge datasets, involving yea
We compare the absolute gain photometric calibration of the Planck/HFI and Herschel/SPIRE instruments on diffuse emission. The absolute calibration of HFI and SPIRE each relies on planet flux measurements and comparison with theoretical far-infrared
We present the NPIPE processing pipeline, which produces calibrated frequency maps in temperature and polarization from data from the Planck Low Frequency Instrument (LFI) and High Frequency Instrument (HFI) using high-performance computers. NPIPE re
We present a parallel implementation of a map-making algorithm for CMB anisotropy experiments which is both fast and efficient. We show for the first time a Maximum Likelihood, minimum variance map obtained by processing the entire data stream expect