ﻻ يوجد ملخص باللغة العربية
The Crab Nebula is the only hard X-ray source in the sky that is both bright enough and steady enough to be easily used as a standard candle. As a result, it has been used as a normalization standard by most X-ray/gamma ray telescopes. Although small-scale variations in the nebula are well-known, since the start of science operations of the Fermi Gamma-ray Burst Monitor (GBM) in August 2008, a ~ 7% (70 mcrab) decline has been observed in the overall Crab Nebula flux in the 15 - 50 keV band, measured with the Earth occultation technique. This decline is independently confirmed with three other instruments: the Swift Burst Alert Telescope (Swift/BAT), the Rossi X-ray Timing Explorer Proportional Counter Array (RXTE/PCA), and the INTErnational Gamma-Ray Astrophysics Laboratory Imager on Board INTEGRAL (IBIS). A similar decline is also observed in the ~3 - 15 keV data from the RXTE/PCA and INTEGRAL Joint European Monitor (JEM-X) and in the 50 - 100 keV band with GBM and INTEGRAL/IBIS. Observations from 100 to 500 keV with GBM suggest that the decline may be larger at higher energies. The pulsed flux measured with RXTE/PCA since 1999 is consistent with the pulsar spin-down, indicating that the observed changes are nebular. Correlated variations in the Crab Nebula flux on a ~3 year timescale are also seen independently with the PCA, BAT, and IBIS from 2005 to 2008, with a flux minimum in April 2007. As of August 2010, the current flux has declined below the 2007 minimum.
Supernova Ia magnitude surveys measure the dimensionless luminosity distance $H_{0}D_{L}$. However, from the distances alone one cannot obtain quantities like $H(z)$ or the dark energy equation of state, unless further cosmological assumptions are im
We investigate the clustering of afterglow light curves observed at X-ray and optical wavelengths. We have constructed a sample of 61 bursts with known dis tance and X-ray afterglow. This sample includes bursts observed by BeppoSAX, XMM-Newton, Chand
The cosmological distance ladder crucially depends on classical Cepheids (with P=3-80 days), which are primary distance indicators up to 33 Mpc. Within this volume, very few SNe Ia have been calibrated through classical Cepheids, with uncertainty rel
Although Type Ia supernova cosmology has now reached a mature state, it is important to develop as many independent methods as possible to understand the true nature of dark energy. Recent studies have shown that Type II supernovae (SNe II) offer suc
The standard candle method for Type II plateau supernovae produces a Hubble diagram with a dispersion of 0.3 mag, which implies that this technique can produce distances with a precision of 15%. Using four nearby supernovae with Cepheid distances I find Ho(V)=75+/-7, and Ho(I)=65+/-12.