ترغب بنشر مسار تعليمي؟ اضغط هنا

Acoustically driven ferromagnetic resonance

120   0   0.0 ( 0 )
 نشر من قبل Mathias Weiler
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Surface acoustic waves (SAW) in the GHz frequency range are exploited for the all-elastic excitation and detection of ferromagnetic resonance (FMR) in a ferromagnetic/ferroelectric (nickel/lithium niobate) hybrid device. We measure the SAW magneto-transmission at room temperature as a function of frequency, external magnetic field magnitude, and orientation. Our data are well described by a modified Landau-Lifshitz-Gilbert approach, in which a virtual, strain-induced tickle field drives the magnetization precession. This causes a distinct magnetic field orientation dependence of elastically driven FMR that we observe in both model and experiment.



قيم البحث

اقرأ أيضاً

We present a time-resolved measurement of magnetization dynamics during ferromagnetic resonance (FMR) in a single layer of Ni81Fe19. Small-angle (<1 deg.) precession of elemental Ni, Fe moments could be measured directly and quantitatively using time -resolved x-ray magnetic circular dichroism (XMCD) in transmission. The high temporal and rotational sensitivity of of this technique has allowed characterization of the phase and amplitude of driven FMR motion at 2.3 GHz, verifying basic expectations for a driven resonance.
Permalloy films with one-dimensional (1D) profile modulation of submicron periodicity are fabricated based on commercially available DVD-R discs and studied using ferromagnetic resonance (FMR) method and micromagnetic numerical simulations. The main resonance position shows in-plane angular dependence which is strongly reminiscent of that in ferromagnetic films with uniaxial magnetic anisotropy. The main signal and additional low field lines are attributed to multiple standing spin wave resonances defined by the grating period. The results may present interest in magnetic metamaterials and magnonics applications.
Understanding the multiferroic coupling is one of the key issues in the feld of multiferroics. As shown here theoretically, the ferromagnetic resonance (FMR) renders possible an access to the magnetoelectric coupling coefficient in composite multifer roics. This we evidence by a detailed analysis and numerical calculations of FMR in an unstrained chain of BaTiO3 in the tetragonal phase in contact with Fe, including the effect of depolarizing field. The spectra of the absorbed power in FMR are found to be sensitive to the orientation of the interface electric polarization and to an applied static electric field. Here we propose a method for measuring the magnetoelectric coupling coefficient by means of FMR.
The magnetization characteristic in a permalloy thin strip is investigated by electrically measuring the anisotropic magnetoresistance and ferromagnetic resonance in in-plane and out-of-plane configurations. Our results indicate that the magnetizatio n vector can rotate in the film plane as well as out of the film plane by changing the intensity of external magnetic field of certain direction. The magnetization characteristic can be explained by considering demagnetization and magnetic anisotropy. Our method can be used to obtain the demagnetization factor, saturated magnetic moment and the magnetic anisotropy.
94 - W. K. Peria , S. Lee (2 2020
We report the experimental observation in thin films of the hybridization of the uniform ferromagnetic resonance mode with nonuniform magnons as a result of the two-magnon scattering mechanism, leading to a frequency-pulling effect on the ferromagnet ic resonance. This effect, when not properly accounted for, leads to a discrepancy in the dependence of the ferromagnetic resonance field on frequency for different field orientations. The frequency-pulling effect is the complement of the broadening of the ferromagnetic resonance lineshape by two-magnon scattering and can be calculated using the same parameters. By accounting for the two-magnon frequency shifts through these means, consistency is achieved in fitting data from in-plane and perpendicular-to-plane resonance conditions.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا