ترغب بنشر مسار تعليمي؟ اضغط هنا

GRAVITY: a four-telescope beam combiner instrument for the VLTI

155   0   0.0 ( 0 )
 نشر من قبل Stefan Gillessen
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

GRAVITY is an adaptive optics assisted Beam Combiner for the second generation VLTI instrumentation. The instrument will provide high-precision narrow-angle astrometry and phase-referenced interferometric imaging in the astronomical K-band for faint objects. We describe the wide range of science that will be tackled with this instrument, highlighting the unique capabilities of the VLTI in combination with GRAVITY. The most prominent goal is to observe highly relativistic motions of matter close to the event horizon of Sgr A*, the massive black hole at center of the Milky Way. We present the preliminary design that fulfils the requirements that follow from the key science drivers: It includes an integrated optics, 4-telescope, dual feed beam combiner operated in a cryogenic vessel; near-infrared wavefrontsensing adaptive optics; fringe-tracking on secondary sources within the field of view of the VLTI and a novel metrology concept. Simulations show that 10 {mu}as astrometry within few minutes is feasible for a source with a magnitude of mK = 15 like Sgr A*, given the availability of suitable phase reference sources (mK = 10). Using the same setup, imaging of mK = 18 stellar sources in the interferometric field of view is possible, assuming a full night of observations and the corresponding UV coverage of the VLTI.



قيم البحث

اقرأ أيضاً

GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imag ing capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.
175 - M.Benisty , J-P.Berger , L.Jocou 2009
The very recent years have seen a promising start in scientific publications making use of images produced by near-infrared long-baseline interferometry. The technique has reached, at last, a technical maturity level that opens new avenues for numero us astrophysical topics requiring milli-arcsecond model-independent imaging. The Very Large Telescope Interferometer (VLTI) is on the path to be equipped with instruments capable to combine between four to six telescopes. In the framework of the VLTI second generation instruments Gravity and VSI, we propose a new beam combining concept using Integrated Optics (IO) technologies with a novel ABCD-like fringe encoding scheme. Our goal is to demonstrate that IO-based combination brings considerable advantages in terms of instrumental design and performance. We therefore aim at giving a full characterization of an IO beam combiner to establish its performances and check its compliance with the specifications of an imaging instrument. Laboratory measurements were made in the H band with a dedicated testbed. We studied the beam combiners through the analysis of throughput, instrumental visibilities, phases and closure phases in wide band as well as with spectral dispersion. Study of the polarization properties is also done. We obtain competitive throughput, high and stable instrumental contrasts, stable but non-zero closure phases which we attribute to internal well calibrable optical path differences. We validate a new static and achromatic phase shifting IO function close to the nominal 90deg value. All these observables show limited chromaticity over the H band range. Our results demonstrate that such ABCD-like beam combiners are particularly well suited to achieve aperture synthesis imaging. This opens the way to extend to all near infrared wavelengths and in particular, the K band.
We present the adaptive optics assisted, near-infrared VLTI instrument - GRAVITY - for precision narrow-angle astrometry and interferometric phase referenced imaging of faint objects. Precision astrometry and phase-referenced interferometric imaging will realize the most advanced vision of optical/infrared interferometry with the VLT. Our most ambitious science goal is to study motions within a few times the event horizon size of the Galactic Center massive black hole and to test General Relativity in its strong field limit. We define the science reference cases for GRAVITY and derive the top level requirements for GRAVITY. The installation of the instrument at the VLTI is planned for 2012.
PIONIER stands for Precision Integrated-Optics Near-infrared Imaging ExpeRiment. It combines four 1.8m Auxilliary Telescopes or four 8m Unit Telescopes of the Very Large Telescope Interferometer (ESO, Chile) using an integrated optics combiner. The i nstrument has been integrated at IPAG starting in December 2009 and commissioned at the Paranal Observatory in October 2010. It provides scientific observations since November 2010. In this paper, we detail the instrumental concept, we describe the standard operational modes and the data reduction strategy. We present the typical performance and discuss how to improve them. This paper is based on laboratory data obtained during the integrations at IPAG, as well as on-sky data gathered during the commissioning at VLTI. We illustrate the imaging capability of PIONIER on the binaries deltaSco and HIP11231. PIONIER provides 6 visibilities and 3 independent closure phases in the H band, either in a broadband mode or with a low spectral dispersion (R=40), using natural light (i.e. unpolarized). The limiting magnitude is Hmag=7 in dispersed mode under median atmospheric conditions (seeing<1, tau0>3ms) with the 1.8m Auxiliary Telescopes. We demonstrate a precision of 0.5deg on the closure phases. The precision on the calibrated visibilities ranges from 3 to 15% depending on the atmospheric conditions. PIONIER has been installed and successfully tested as a visitor instrument for the VLTI. It permits high angular resolution imaging studies at an unprecedented level of sensitivity. The successful combination of the four 8m Unit Telescopes in March 2011 demonstrates that VLTI is ready for 4-telescope operation.
The VLTI instrument GRAVITY combines the beams from four telescopes and provides phase-referenced imaging as well as precision-astrometry of order 10 microarcseconds by observing two celestial objects in dual-field mode. Their angular separation can be determined from their differential OPD (dOPD) when the internal dOPDs in the interferometer are known. Here, we present the general overview of the novel metrology system which performs these measurements. The metrology consists of a three-beam laser system and a homodyne detection scheme for three-beam interference using phase-shifting interferometry in combination with lock-in amplifiers. Via this approach the metrology system measures dOPDs on a nanometer-level.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا