ترغب بنشر مسار تعليمي؟ اضغط هنا

Wide spin resonance with an rf-bunched proton beam

105   0   0.0 ( 0 )
 نشر من قبل A. D. Krisch
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We recently used an rf solenoid to study the widths of rf spin resonances with both unbunched and bunched beams of 2.1 GeV_c polarized protons stored in the COSY synchrotron. A map, with unbunched beam at different fixed rf-solenoid frequencies, showed a very shallow possible depolarization dip at the resonance. Next we made frequency sweeps of 400Hz, centered at similar frequencies, which greatly enhanced the dip. But, with a bunched proton beam, both the fixed-frequency and frequency-sweep techniques produced similar maps, and both bunched maps showed full beam depolarization over a wide region. Moreover, both were more than twice as wide as the unbunched dip. This widening of the proton resonance due to bunching is exactly opposite to the recently observed narrowing of deuteron resonances due to bunching.



قيم البحث

اقرأ أيضاً

A method proposed to preserve the electron beam polarization at the VEPP-4M collider during acceleration with crossing the integer (imperfection) spin resonance at energy E=1763 MeV has been successfully applied. It is based on full decompensation of the $ 0.6times3.3$ Tesla$times$meter integral of the KEDR detector longitudinal magnetic field due to the anti-solenoids switched-off.
There has been much interest in the blowout regime of plasma wakefield acceleration (PWFA), which features ultra-high fields and nonlinear plasma motion. Using an exact analysis, we examine here a fundamental limit of nonlinear PWFA excitation, by an infinitesimally short, relativistic electron beam. The beam energy loss in this case is shown to be linear in charge even for nonlinear plasma response, where a normalized, unitless charge exceeds unity. The physical basis for this effect is discussed, as are deviations from linear behavior observed in simulations with finite length beams.
133 - W. Chou , D. Capista , J. Griffin 2008
Two barrier RF systems were fabricated, tested and installed in the Fermilab Main Injector. Each can provide 8 kV rectangular pulses (the RF barriers) at 90 kHz. When a stationary barrier is combined with a moving barrier, injected beams from the Boo ster can be continuously deflected, folded and stacked in the Main Injector, which leads to doubling of the beam intensity. This paper gives a report on the beam experiment using this novel technology.
150 - K. Cornelis 2014
During the proton-anti proton collider run several experiments were carried out in order to understand the effect of the beam-beam interaction on backgrounds and lifetimes. In this talk a selection of these experiments will be presented. From these e xperiments, the importance of relative beam sizes and tune ripple could be demonstrated.
This submission was withdrawn because of an unresolved dispute between the authors [arXiv admin 2009-4-13].
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا