ترغب بنشر مسار تعليمي؟ اضغط هنا

Technical aspects and dark matter searches

174   0   0.0 ( 0 )
 نشر من قبل Pierluigi Belli
 تاريخ النشر 2009
  مجال البحث فيزياء
والبحث باللغة English
 تأليف R. Bernabei




اسأل ChatGPT حول البحث

A variety of detectors has been proposed for dark matter direct detection, but most of them -- by the fact -- are still at R&D stage. In many cases, it is claimed that the lack of an adequate detectors radio-purity might be compensated through heavy uses of MonteCarlo simulations, subtractions and handlings of the measured counting rates, in order to claim higher sensitivity (just for a particular scenario). The relevance of a correct evaluation of systematic effects in the use of MonteCarlo simulations at very low energy (which has always been safely discouraged in the field so far) and of multiple subtractions and handling procedures applied to the measured counting rate is shortly addressed here at some extent. Many other aspects would also deserve suitably deep investigations.



قيم البحث

اقرأ أيضاً

127 - R. Cerulli 2012
Some theoretical and experimental aspects regarding the direct dark matter field are mentioned. In particular some arguments, which play a relevant role in the evaluation of model dependent interpretations of experimental results and in comparisons, are shortly addressed.
Sensitivities of current directional dark matter search detectors using gas time projection chambers are now constrained by target mass. A ton-scale gas TPC detector will require large charge readout areas. We present a first demonstration of a novel ThGEM-Multiwire hybrid charge readout technology which combines the robust nature and high gas gain of Thick Gaseous Electron Multipliers with lower capacitive noise of a one-plane multiwire charge readout in SF$_6$ target gas. Measurements performed with this hybrid detector show an ion drift velocity of $139~pm~12~text{ms}^{-1}$ in a reduced drift field $text{E/N}$ of $93~text{Td}~(10^{-17}~text{V cm}^{2})$ at a gas gain of $2470pm160$ in 20 Torr of pure SF$_text{6}$ target gas.
The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact g ermanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.
302 - M.Bassan , E.Coccia , S.DAntonio 2015
Many experiments have searched for supersymmetric WIMP dark matter, with null results. This may suggest to look for more exotic possibilities, for example compact ultra-dense quark nuggets, widely discussed in literature with several different names. Nuclearites are an example of candidate compact objects with atomic size cross section. After a short discussion on nuclearites, the result of a nuclearite search with the gravitational wave bar detectors Nautilus and Explorer is reported. The geometrical acceptance of the bar detectors is 19.5 $rm m^2$ sr, that is smaller than that of other detectors used for similar searches. However, the detection mechanism is completely different and is more straightforward than in other detectors. The experimental limits we obtain are of interest because, for nuclearites of mass less than $10^{-5}$ g, we find a flux smaller than that one predicted considering nuclearites as dark matter candidates. Particles with gravitational only interactions (newtorites) are another example. In this case the sensitivity is quite poor and a short discussion is reported on possible improvements.
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time projection chamber (TPC) sensitive to nuclear recoils resulting from scattering of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets. With an activ e target of 850 kg, ArDM represents an important milestone in the quest for Dark Matter with LAr. We present the experimental apparatus currently installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain. We show first data recorded during a single-phase commissioning run in 2015 (ArDM Run I), which overall confirm the good and stable performance of the ton-scale LAr detector.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا