MPGDs in Compton imaging with liquid-xenon


الملخص بالإنكليزية

The interaction of radiation with liquid xenon, inducing both scintillation and ionization signals, is of particular interest for Compton-sequences reconstruction. We report on the development and recent results of a liquid-xenon time-projection chamber, dedicated to a novel nuclear imaging technique named 3 gamma imaging. In a first prototype, the scintillation is detected by a vacuum photomultiplier tube and the charges are collected with a MICROMEGAS structure; both are fully immersed in liquid xenon. In view of the final large-area detector, and with the aim of minimizing dead-zones, we are investigating a gaseous photomultiplier for recording the UV scintillation photons. The prototype concept is presented as well as preliminary results in liquid xenon. We also present soft x-rays test results of a gaseous photomultiplier prototype made of a double Thick Gaseous Electron Multiplier (THGEM) at normal temperature and pressure conditions.

تحميل البحث