ترغب بنشر مسار تعليمي؟ اضغط هنا

Development and Application of a Diaphragm Micro-Pump with Piezoelectric Device

97   0   0.0 ( 0 )
 نشر من قبل EDA Publishing Association
 تاريخ النشر 2008
  مجال البحث الهندسة المعلوماتية
والبحث باللغة English




اسأل ChatGPT حول البحث

In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate the liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 5mm x 8mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow which may change the chamber volume by changing the curvature of a diaphragm. Several experimental set-ups for performance test in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system is designed and implemented. The performance of one-side actuating micro-diaphragm pump is affected by the design of check valves, diaphragm, piezoelectric device, chamber volume, input voltage and frequency. The measured maximum flow rate of present design is 72 ml/min at zero total pump head in the range of operation frequency 70-180 Hz.



قيم البحث

اقرأ أيضاً

In this paper, we presented the design and development of a new integrated device for measuring heart rate using fingertip to improve estimating the heart rate. As heart related diseases are increasing day by day, the need for an accurate and afforda ble heart rate measuring device or heart monitor is essential to ensure quality of health. However, most heart rate measuring tools and environments are expensive and do not follow ergonomics. Our proposed Heart Rate Measuring (HRM) device is economical and user friendly and uses optical technology to detect the flow of blood through index finger. Three phases are used to detect pulses on the fingertip that include pulse detection, signal extraction, and pulse amplification. Qualitative and quantitative performance evaluation of the device on real signals shows accuracy in heart rate estimation, even under intense of physical activity. We compared the performance of HRM device with Electrocardiogram reports and manual pulse measurement of heartbeat of 90 human subjects of different ages. The results showed that the error rate of the device is negligible.
144 - Patrick Sangouard 2008
This work relates to a novel piezoelectric transformer to be used in an autonomous sensor unit, possibly in conjunction with a RF-MEMS retro-modulator.
The present study presents a new micro electromagnetic actuator utilizing a PDMS membrane with a magnet. The actuator is integrated with micro coils to electromagnetically actuate the membrane and results in a large deflection. The micro electromagne tic actuator proposed in this study is easily fabricated and is readily integrated with existing bio-medical chips due to its planar structure.
244 - X.-C. Shan , S.H. Ling , H. P. Maw 2008
Multilayered ceramic substrates with embedded micro patterns are becoming increasingly important, for example, in harsh environment electronics and microfluidic devices. Fabrication of these embedded micro patterns, such as micro channels, cavities a nd vias, is a challenge. This study focuses on the process of patterning micro features on ceramic green substrates using micro embossing. A ceramic green tape that possessed near-zero shrinkage in the x-y plane was used, six layers of which were laminated as the embossing substrate. The process parameters that impact on the pattern fidelity were investigated and optimized in this study. Micro features with line-width as small as several micrometers were formed on the ceramic green substrates. The dynamic thermo-mechanical analysis indicated that extending the holding time at certain temperature range would harden the green substrates with little effect on improving the embossing fidelity. Ceramic substrates with embossed micro patterns were obtain d after co-firing. The embedded micro channels were also obtained by laminating the green tapes on the embossed substrates.
301 - L. Grasser 2008
Parametric amplification is an interesting way of artificially increasing a MEMS Quality factor and could be helpful in many kinds of applications. This paper presents a theoretical study of this principle, based on Matlab/Simulink simulations, and p roposes design guidelines for parametric structures. A new device designed with this approach is presented together with the corresponding FEM simulation results.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا