الكالوريميتر الهادرون المصقول بالبلاط الشمعي الجديد مع قراءة SiPM

Scintillator Tile Hadron Calorimeter with Novel SiPM Readout

778   0   0.0 ( 0 )
 نشر من قبل Mikhail Danilov
 تاريخ النشر 2007
  مجال البحث فيزياء
والبحث باللغة English
 تأليف M.Danilov




اسأل ChatGPT حول البحث

The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a large scale. We present the design of the HCAL and report on measured properties of more than 10 thousand SiPMs. We discuss the SiPM efficiency, gain, cross-talk, and noise rate dependence on bias voltage and temperature, including the spread in these parameters. We analyze the reasons for SiPM rejection and present the results of the long term stability studies. The first measurements of the SiPM radiation hardness are presented. We compare properties of SiPM with the properties of similar devices, MRS APD and MPPC. A possibility to make the tiles thinner and to read them out without WLS fibers has been studied.



قيم البحث

اقرأ أيضاً

The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers (SiPMs) as active material (SiPM-on-tile). The front-end chips are integrated into the active layers of the calorimeter and are designed for minimizing power consumption by rapidly cycling the power according to the beam structure of a linear accelerator. 38 layers of the sampling structure are equipped with cassettes containing 576 single channels each, arranged on readout boards and grouped according to the 36 channel readout chips. The prototype has been assembled using techniques suitable for mass production, such as injection-moulding and semi-automatic wrapping of scintillator tiles, assembly of scintillators on electronics using pick-and-place machines and mass testing of detector elements. The calorimeter was commissioned at DESY and was taking data at the CERN SPS at the time of the conference. The contribution discusses the construction, commissioning and first test beam results of the CALICE AHCAL engineering prototype.
The present article introduces a novel ASIC architecture, designed in the context of the ATLAS Tile Calorimeter upgrade program for the High-Luminosity phase of the Large Hadron Collider at CERN. The architecture is based on radiation-tolerant 130 nm Complementary Metal-Oxide-Semiconductor technology, embedding both analog and digital processing of detector signals. A detailed description of the ASIC is given in terms of motivation, design characteristics and simulated and measured performance. Experimental studies, based on 24 prototype units under real particle beam conditions are also presented in order to demonstrate the potential of the architecture as a reliable front-end readout electronic solution.
77 - S. Lee , A. Cardini , M. Cascella 2017
In this paper, we describe measurements of the response functions of a fiber-based dual- readout calorimeter for pions, protons and multiparticle jets with energies in the range from 10 to 180 GeV. The calorimeter uses lead as absorber material and h as a total mass of 1350 kg. It is complemented by leakage counters made of scintillating plastic, with a total mass of 500 kg. The effects of these leakage counters on the calorimeter performance are studied as well. In a separate section, we investigate and compare different methods to measure the energy resolution of a calorimeter. Using only the signals provided by the calorimeter, we demonstrate that our dual-readout calorimeter, calibrated with electrons, is able to reconstruct the energy of proton and pion beam particles to within a few percent at all energies. The fractional widths of the signal distributions for these particles (sigma/E) scale with the beam energy as 30%/sqrt(E), without any additional contributing terms.
High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied co unter sizes up to $120times40times5$ mm^3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resolution. A readout scheme with analog shaping and digital waveform analysis is optimized to achieve the highest time resolution. The timing performance is measured using electrons from a Sr-90 radioactive source, comparing different scintillators, counter dimensions, and types of near-ultraviolet sensitive SiPMs. As a result, a resolution of $sigma =42 pm 2$ ps at 1 MeV energy deposition is obtained for counter size $60times 30 times 5$ mm^3 with three SiPMs ($3times3$ mm^2 each) at each end of the scintillator. The time resolution improves with the number of photons detected by the SiPMs. The SiPMs from Hamamatsu Photonics give the best time resolution because of their high photon detection efficiency in the near-ultraviolet region. Further improvement is possible by increasing the number of SiPMs attached to the scintillator.
CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory. Calorimeter is the main part of this experiment to measure the jet ene rgy. Semi-digital hadron calorimeter (SDHCAL) is one of the options for the hadron measurement. GEM detector with its high position resolution and flexible configuration is one of the candidates for the active layer of the SDHCAL. The main purpose of this paper is to provide a feasible readout method for the GEM-based semi-digital hadron calorimeter. A small-scale prototype is designed and implemented, including front-end board (FEB) and data interface board (DIF). The prototype electronics has been tested. The equivalent RMS noise of all channels is below 0.35fC. The dynamic range is up to 500fC and the gain variation is less than 1%. The readout electronics is applied on a double-layer GEM detector with 1cm*1cm readout pad. Result indicates that the electronics works well with the detector. The detection efficiency of MIP is over 95% with 5fC threshold.